IN FIELD OPERATION
OPERATORS MANUAL - HYBRID - M3F & M4RF
Press and hold calibration button
until the metering starts.
Allow metering unit to release
a suitable amount of product to
achieve an accurate weight to be
calibrated.
To stop the metering unit, press
and hold the calibration button
until the metering stops.
Step 4
Place bucket or appropriate container
under venturi as per image.
Step 3
1. Container
IMPORTANT
Prior to initiating the calibration process it is important to purge the
metering unit. (This only needs to be done once). Press and hold the
calibration button until the metering has started. Once the metering
has completed at least
1
revolution to ensure the metering unit is full
of product. Press and hold the button again to stop. Catch any product
in the container and return to hopper or discard.
!
!