background image

17

PRELIMINARY

STORMY       C71090

STORMY CC C71091 

INFORMATION MENU - 

DMX MONITOR

It allows to visualize the DMX input level (in bits or as a percentage) of each channel of the projector (value 

Between 0 and 255 bit or between 0 and 100%).

INFORMATION MENU - 

FANS MONITOR

It allows to display the rotation speed (

RPM Speed

) of the fans installed on the machine.

PwrSp

 = Power Supply fans.

5.4 MANUAL CONTROL MENU

MANUAL CONTROL - 

RESET

It allows to reset the projector’s CPU in case of anomalies.

MANUAL CONTROL - 

CHANNEL

It allows to set a value in bit to the channels, from the projector control panel for manual control of each effect 

without the need of a DMX input signal (values between 0 and 255 bits).

5.5 ADVANCED MENU

To access to the Advanced menu (only recommended for experienced users), you need to set the access 

code 1234.

ADVANCED MENU - 

FIRMWARE UPLOAD

It allows to transfer the firmware from one projector to the others connected to it.

ADVANCED MENU - 

MODEL SETUP

It allows to change the projector’s model set, selecting among the available:

•   Undefined

•   Stormy

•   Stormy  CC

Содержание STORMY

Страница 1: ...The latest LED technology meets the charm of a classic strobe INSTRUCTION MANUAL STORMY C71090 STORMY CC C71091 www claypaky it STORMY STORMY CC PRELIMINARY AN OSRAM BUSINESS...

Страница 2: ...keep it safe for future reference It is essential to know the information supplied in this manual in order to ensure that the fitting is installed used and serviced correctly and safely CLAY PAKY S p...

Страница 3: ...Options Menu 5 3 Information Menu 5 4 Manual Control Menu 5 5 Advanced Menu 6 Maintenance 7 Accessories 8 Technical Data 8 1 A Technical Data Stormy 8 1 B Technical Data Stormy CC 9 Channels 9 1 A Ch...

Страница 4: ...evaluate the maximum num ber of devices to be connected to the mains to avoid overloads The user must determine in consultation with the supply authority that the equipment is connected only to a supp...

Страница 5: ...ure indicata la potenza assorbita Fare riferimento a quest ultima per valutare il numero massimo di apparecchi da collegare alla linea elettrica al fine di evitare sovraccarichi L utilizzatore deve as...

Страница 6: ...uer le num ro maximal de dispositifs qui peuvent tre connect s la ligne lectrique afin d viter les surcharges L utilisateur doit s assurer apr s la consultation de son fournisseur d lectricit que l ap...

Страница 7: ...n wie viele Ger te maximal an die Stromleitung angeschlossen werden k nnen ohne diese zu berlasten ist die Leistungsaufnahme zu ber cksichtigen Der Benutzer hat nach der Einholung von Informationen be...

Страница 8: ...ntrada Consulte sta ltima para evaluar el n mero m ximo de aparatos que pueden ser conectados a la l nea el ctrica con el fin de evitar sobrecargas El usuario debe verificar tras haber consultado la e...

Страница 9: ...1091 2 UNPACKING AND PREPARATION UNPACKING AND PREPARATION Fig 1 Packing content 1 The latest LED technology meets the charm of a classic strobe INSTRUCTION MANUAL STORMY C71090 STORMY CC C71091 www c...

Страница 10: ...on a truss on the ceiling or wall WARNING the safety chain must be installed except when the projector rests on the floor Code 105015 801 avai lable upon request This must be secured to the projector...

Страница 11: ...11 PRELIMINARY 3 INSTALLATION AND START UP INSTALLATION AND START UP Fig 3 4 Connecting and disconnecting the power cord 3 4 STORMY C71090 STORMY CC C71091...

Страница 12: ...se microphone cable or other cable with characteri stics differing from those specified End connections must be made using XLR type 3 pin male fe male connectors A terminating plug must be inserted on...

Страница 13: ...ything exits the function Decreases the value displayed with auto repetitions or passes to the next item on the menu For quick access to the minimum parameter value press the UP key while holding down...

Страница 14: ...Fixture hours Fixiture hours Lamp hours System Version Strobe firmware Boot firmware Driver firmware CPU board CPU SN Driver diagnostic LED Temperature Current Maximum Minimum Driver Temperature Curr...

Страница 15: ...Curve 2 OPTION MINIMUM TON VALUE It allows the set the minimum T ON duration of strobe flash under which it s not possible to come down It s possible to select a value between 0 and 255 With the Dura...

Страница 16: ...rmware hardware versions of installed machine components Strobe firmware Strobe application firmware Boot firmware Safety software Driver firmware Driver application firmware CPU board Hardware revisi...

Страница 17: ...o reset the projector s CPU in case of anomalies MANUAL CONTROL CHANNEL It allows to set a value in bit to the channels from the projector control panel for manual control of each effect without the n...

Страница 18: ...INARY 6 MAINTENANCE MAINTENANCE 8 Fig 8 Fuses replacing Each product has 2 fuses associated with the main power cord connection Continued STORMY C71090 STORMY CC C71091 2 Fusibili 6 3 x 32 mm 12AT p n...

Страница 19: ...iquid glass cleaning detergent It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cl...

Страница 20: ...20 PRELIMINARY 7 ACCESSORIES ACCESSORIES Fig 10 Barn doors C71116 STORMY C71090 STORMY CC C71091 10 11 1 2...

Страница 21: ...orking position Hanging system with clamps on the bracket OPTICS 42 controlled light 130 direct controlled light COLOR SYSTEM AND EFFECTS SECTION Global dimmer Strobe from 0 3 to 25 flashes sec Xenon...

Страница 22: ...t sink BODY Body extruded in black anodized aluminum Aluminum and steel structure with plastic covers WORKING POSITION Any working position Hanging system with clamps on the bracket OPTICS 42 controll...

Страница 23: ...5msec to longer time 650msec See details in a following dedicated table IMPORTANT Duration Time must be lower than Rate Time Period for flashing If Duration Time is equal or greater than Rate Time Per...

Страница 24: ...lowing dedicated table IMPORTANT Duration Time must be lower than Rate Time Period for flashing If Duration Time is equal or greater than Rate Time Period the light is continuously on RED RATE 0 5 Lig...

Страница 25: ...g dedicated table WHITE INTENSITY 0 255 Blue colour linearly increase from no light to maximum intensity WHITE DURATION 0 255 Light time versus dark time linearly increases from shorter time 2 5msec t...

Страница 26: ...channels 48 63 GREEN overwrites all other channels 64 79 BLUE overwrites all other channels 80 95 WHITE overwrites all other channels 96 11 RED GREEN overwrite BLUE WHITE 112 127 RED BLUE overwrite GR...

Страница 27: ...304 6 120 307 2 121 309 7 122 312 3 123 314 8 124 317 3 125 319 9 126 322 4 127 325 0 128 327 5 DMX level Time msec 129 330 0 130 332 6 131 335 1 132 337 6 133 340 2 134 342 7 135 345 3 136 347 8 137...

Страница 28: ...0 3 79 57 255 0 3 92 58 250 0 4 00 59 245 0 4 08 60 240 0 4 17 61 237 0 4 22 62 234 0 4 27 63 231 0 4 33 64 227 0 4 41 65 224 0 4 46 66 220 0 4 55 67 217 0 4 61 68 214 0 4 67 69 211 0 4 74 70 208 0 4...

Страница 29: ...2 182 77 6 12 89 183 77 2 12 95 184 76 8 13 02 185 76 4 13 09 186 76 0 13 16 187 75 6 13 23 188 75 2 13 30 189 74 8 13 37 190 74 4 13 44 191 74 0 13 51 192 73 6 13 59 193 73 2 13 66 194 72 8 13 74 195...

Страница 30: ...BLUE 2 0A WHITE 2 0A CONT RED 1 0A GREEN 1 0A BLUE 1 5A WHITE 1 5A MAX CURRENT vs TIME ON MAX Max Current MAX RED 2 0A GREEN 2 0A CURRENTVALUES SUBMAX RED 1 5A GREEN 1 5A CONT RED 1 0A GREEN 1 0A Dut...

Отзывы: