no shutdown
If you are disabling the interface, enter the command:
shutdown
D.
To enable another port, enter the command:
exit
and perform the procedures described in Steps B and C.
If finished enabling ports, enter this series commands to return to the ATCA-2210#
prompt:
exit
exit
exit
If you are asked to save changes, enter y for yes or n for no. If you choose yes, this
configuration will be saved as the startup configuration.
3.
To log off from the SFB, enter the command:
exit
4.
If you have two SFBs installed, repeat these steps on the other SFB.
Verify Shelf Manager Operation
These steps confirm that
Shelf Manager
software application is operating when the SFB is
installed in the SC6300 Series Chassis.
1.
Verify that you are at the prompt:
ATCA-2210#
If you are not at the appropriate prompt, see
Connecting to an External Computer and
Network
above on how to get there.
2.
To the get to the
Platform Management Command Line Interface
(CLI), enter the command:
platform-mgmt
3.
To verify that the
Shelf Manager
is started, enter the command:
shelf-mgmt show all
If
Status
is
Unknown
instead of
Active
or
Standby
, the Shelf Manager is not operational and
troubleshooting is required.
4.
To exit the CLI, enter the command:
Chapter 6: SF6090 Switch Fabric Blade
Installation
24