Clavia DMI
Service manual Nord Lead 2x rev. 1.1
Page 7
Opening the synth
WARNING
: Take necessary precautions against ESD before opening the synth.
Nord Lead 2X
Loosen the screws as shown in
the figure. (9x40018)
The two screws on the sides
work as hinges. Lift in the front
to open the top.
Nord Lead 2
(8x40018)
Nord Rack 2/2X
Unscrew the 4 panel screws
(40018)
Gently slide the top
forward and lift it of.
Picture shows Nord Lead 2X
Removing the Power Supply Unit
Loosen the five screws
(40262)
holding the PSU to the chassis. Loosen the two screws
(40013)
on the back panel next to the AC socket. Finally remove the 10 pole ribbon cable
(22340)
and lift out the PSU.
Removing the Main Board
Loosen the three screws
(40262)
holding the main board to the chassis. Loosen the nuts
and remove the washers around the ¼" jacks on the back panel. Also loosen the four
screws
(40010)
holding the MIDI jacks to the chassis. Remove the 20 pole ribbon cable
(22400)
to the panel board, the 10 pole ribbon cable
(22430)
to the PSU and the two
ribbon cables
(22290)
to the keyboard.
You can now lift out the main board.
Removing the Panel Board
Pull off all knobs
(22900)
on the front panel (not the buttons). Remove the ribbon cable
(22400)
from the panel board. Loosen the last two screws
(40018)
holding the top to the
chassis. Loosen the nine screws
(40262)
holding the panel board to the upper lid.
You can now lift out the panel board.
Содержание Nord Lead 2X
Страница 1: ...SERVICE MANUAL...