Clavia Nord Lead 2X Скачать руководство пользователя страница 5

                                                                                                                                            

 

Clavia DMI 

Service manual Nord Lead 2x rev. 1.1 

Page 4 

 

Test program 

 

Running the test program 
 

In order to trace a hardware error easier, each Nord synthesizer has a test program. 
This program is primarily used in production in order to test all functions.  
The functions provided by the test program allow a quick and easy search for possible 
errors in the hardware.

 

 

WARNING:

 Improper use of the test program or powering off the synth during a test 

can result in malfunction of the synth. The test program may only be used by qualified 
service personnel and is not intended for end users.  

 
Navigating through the test program

  

In order to execute the different tests on a Nord Lead 2/2X, first make sure power is 
turned on. Press 

[ SHIFT +  SLOT X ]

 where X stands for one of the 

following tests: 
  

A:

 Knob test. Turn each knob fully counter clockwise, fully clockwise and then fully 

counter clockwise again. A completely tested knob is indicated by a dot and a hyphen. 
The knobs has to be turned in order, starting with the Master Level. Find the next knob 
by first trying the one closest to the previous position. Exit the test with the 

[ PANIC ]

 

button. Reset the test with the 

[ DEMO ] 

button. If an error shows up, try performing 

the simple knob test described in the next section.  

B:

 Button test. Pressing each button should turn on the corresponding LED or LED 

group. The buttons have to be pressed in order, starting with 

[ CLEAR ]

. Find the next 

knob by first trying the one closest to the previous position. Once a knob has been lit, 
it cannot be switched off. Pressing all the buttons exits the test. You can also exit the 
test manually by pressing the 

[ PANIC ]

 button.  

C:

 Pitch stick calibration test. Tests that the pitch stick is calibrated. The value shown in 

the display should be between 72 and 96. If the value is too small, this is indicated by 
a dot. If the value is too large, this is indicated by a hyphen. Exit the test by pressing 
the 

[ PANIC ]

 button.  

D:

 Button and pitch stick test. This test differs from the tests above in a way that the 

knobs do not have to be turned in any specific order. However, a knob must be fully 
tested before the next one can be tested. This is done by turning a knob fully counter 
clockwise, fully clockwise and then fully counter clockwise again.  
A completely tested knob is indicated by a dot and a hyphen.  
The pitch stick is tested by moving it fully to the left, then right and finally to the left 
again. Hold the pitch stick in the leftmost position in order to continue testing another 
function.  

 
 
 
 
 
 

Содержание Nord Lead 2X

Страница 1: ...SERVICE MANUAL...

Страница 2: ...2x rev 1 1 Page 1 Table of contents Overview 3 Test program 4 Running the test program 4 Calibrating the DACs 5 Hardware 6 Hardware structure 6 Opening the synth 7 Hardware configuration 8 Hardware v...

Страница 3: ...d from other web pages made into derivative works or distributed to other sources such as end users or retailers that do not repair Clavia products IInformation is only valid for Nord Lead Rack 2 when...

Страница 4: ...in total with 64 kB PCMCIA expansion card 4 x 99 user programs 100 user performances 4 x 10 user percussion kits 6 x 99 factory programs 3 x 100 factory performances Audio Quality 18bit 44 1 kHz 24 b...

Страница 5: ...test with the DEMO button If an error shows up try performing the simple knob test described in the next section B Button test Pressing each button should turn on the corresponding LED or LED group T...

Страница 6: ...e function of a single output first make sure the synth is on Enter performance mode by pressing PERF MODE and then press SHIFT OSC KBD TRACK This should output a clean sine wave on output A when pres...

Страница 7: ...place on the panel board see schematic for details All input and output jacks are filtered from radio signals with an EMI filter External connectors are a 10 pole connector for the power supply unit...

Страница 8: ...remove the 10 pole ribbon cable 22340 and lift out the PSU Removing the Main Board Loosen the three screws 40262 holding the main board to the chassis Loosen the nuts and remove the washers around th...

Страница 9: ...are versions Main board BootPROM Notes ver 0 4 V1 0 Software Uploading OS and sounds The software version is briefly shown on the LED display when you power up the Nord Lead 2X To update the software...

Страница 10: ...eeel 40262 Screw M4x6 40010 Screw midi 40013 Screw AC input 40017 Screw keyboardNL2 transformer 40025 Screw modulation wheel 40026 Screw pitch stick upper lid 40018 Screw upper lower lid 40208 spacer...

Страница 11: ...080 Crystal 32 768 KHz SMD 22600 Connector 1 4 Stereo 22590 Connector 1 4 Mono 22640 Connector din 5pol Midi 22670 Connector 16 pole micromatch 22500 Connector 20 pole 22480 Connector 10pol Power boar...

Отзывы: