41001333 iss 01
Fig 3
WIRING DIAGRAM
NOTE: The unit MUST be reliably earthed
.
OPERATION
This heater is controlled by a Celsia Zone Controller CZC1 and can
only be used when connected.
Each CZC1 can control any number
of heaters. The heater has an indicator light positioned on the fascia
panel on the top left side. The light may be:
Green
-
when no heat is needed
Yellow
-
when some heat is needed to maintain
the room temperature
Red
-
when the heater is on full power
Fast Flashing Red -
when the heater has overheated and an
Electronic Safety Control has switched
the heater off.
Please refer to the user and operating instructions for the CZC1 for
detailed instructions.
ELECTRONIC SAFETY CONTROL
The appliance is fitted with an Electronic Safety Control (ES). This is
a safety device which switches the heater off if, for any reason, the
appliance overheats. The overheating is indicated by fast flashing
red light. The ES control can only be re-set after the appliance has
cooled down. In order to re-set the ES control, proceed as follows:
•
Switch the appliance off at the mains by using the isolator
switch and leave to cool down for approximately 5 minutes.
•
Switch appliance back on and the ES control will re-set.
Ensure that the appliance is functioning correctly. If the ES control
operates again, the appliance should be checked by a competent
electrician.
MAINTENANCE
Always ensure that the main external electricity supply is switched
off before attending to the servicing of your Claudgen Screen-Zone
heater.
To obtain best results from your heater it is necessary to avoid the
build up of dust and dirt within the unit and on the air inlet and
discharge grills. For this reason regular cleaning is necessary, paying
particular attention to the removal of dirt build up on the rotor
blades. A single drop of light oil should be applied to the motor
bearing from time to time.
TO REPLACE THE FAN HEATER ASSEMBLY
a)
Remove the top cover.
b)
Disconnect the internal wiring from the main terminal block and
earth stud.
c)
Release the three fixings which secure the switch bracket to the
right hand of the main case.
d)
Remove the four nuts and washers fixing the fan heater
assembly to the back of the case.
e)
The fan heater assembly can now be eased forward and
removed from the heater case.
f)
Fit replacement fan heater and reassemble in reverse order.
SPARES
It is essential when ordering spares or replacement parts to state the
model number and the serial number on the rating place fixed to the
top of the unit.
In the interest of progress the Company reserve the right to vary
specifications from time to time without notice. The material listed
is offered subject to the Company’s General Conditions of Sale, a
copy of which can be obtained on request.
NOTE: DO NOT COVER any of the air inlet or outlet grills, at any
time.