background image

41001333 iss 01 

 
 
Fig 3

 

WIRING DIAGRAM 

 
 
 
 

 

 
 
 
 

NOTE: The unit MUST be reliably earthed

 
 
 
 
 
 
 
 
 
 

OPERATION 

This heater is controlled by a Celsia Zone Controller CZC1 and can 
only be used when connected. 

 Each CZC1 can control any number 

of heaters.  The heater has an indicator light positioned on the fascia 
panel on the top left side.  The light may be: 
 

Green

 

-

 

when no heat is needed 

Yellow

 

-

 

when some heat is needed to maintain 

 

 

the room temperature 

Red

 

-

 

when the heater is on full power 

 

Fast Flashing Red  - 

when the heater has overheated and an 

 

 

Electronic Safety Control has switched 

 

 

the heater off. 

 

Please  refer  to  the  user  and  operating  instructions  for  the  CZC1  for 
detailed instructions. 

 
 

ELECTRONIC SAFETY CONTROL 

The appliance is fitted with an Electronic Safety Control (ES).  This is 
a safety device which switches the heater off if, for any reason, the 
appliance overheats.  The overheating is indicated by fast flashing 
red light.  The ES control can only be re-set after the appliance has 
cooled down.  In order to re-set the ES control, proceed as follows: 
 

 

Switch the appliance off at the mains by using the isolator 
switch and leave to cool down for approximately 5 minutes. 

 

Switch appliance back on and the ES control will re-set. 

Ensure that the appliance is functioning correctly.  If the ES control 
operates  again,  the  appliance  should  be  checked  by  a  competent 
electrician. 

 

MAINTENANCE

 

Always  ensure  that  the  main  external  electricity  supply  is  switched 
off  before  attending  to  the  servicing  of  your  Claudgen  Screen-Zone 
heater. 
 
To  obtain  best  results  from  your  heater  it  is  necessary  to  avoid  the 
build  up  of  dust  and  dirt  within  the  unit  and  on  the  air  inlet  and 
discharge grills.  For this reason regular cleaning is necessary, paying 
particular  attention  to  the  removal  of  dirt  build  up  on  the  rotor 
blades.    A  single  drop  of  light  oil  should  be  applied  to  the  motor 
bearing from time to time. 

 

 
 

TO REPLACE THE FAN HEATER ASSEMBLY

 

a)

 

Remove the top cover. 

b)

 

Disconnect the internal wiring from the main terminal block and 
earth stud. 

c)

 

Release the three fixings which secure the switch bracket to the 
right hand of the main case. 

d)

 

Remove  the  four  nuts  and  washers  fixing  the  fan  heater 
assembly to the back of the case. 

e)

 

The  fan  heater  assembly  can  now  be  eased  forward  and 
removed from the heater case. 

f)

 

Fit replacement fan heater and reassemble in reverse order. 

 
 

SPARES

 

It is essential when ordering spares or replacement parts to state the 
model number and the serial number on the rating place fixed to the 
top of the unit. 
 
In  the  interest  of  progress  the  Company  reserve  the  right  to  vary 
specifications from time to time without notice.  The material listed 
is  offered  subject  to  the  Company’s  General  Conditions  of  Sale,  a 
copy of which can be obtained on request. 
 

NOTE:  DO NOT COVER any of the air inlet or outlet grills, at any 
time.

 