Classeq Under Counter Range - User Manual
7
UK
4.
Installation
Warning!
The installer and user are responsible for
ensuring the installation and operation of this
warewasher
are in accordance with this manual
and with local and national regulations.
4.1
Recommended Hand Tools
The following hand tools are required when installing the
warewasher:
Spirit level
8mm spanner
Multimeter or voltmeter
Insulated No. 2 Posi screw driver
Drill with 8mm bit
4.2
Warewasher Placement
Your warewasher should be installed on a flat, stable surface that
is capable of holding the full weight of the filled warewasher and
withstanding the vibration of regular use
Ensure there is a minimum of 10mm clearance on each side of
your warewasher and 20 mm clearance at the top of the
warewasher (
).
Once your warewasher is in its final position, adjust the
adjustable feet to ensure the warewasher is stable, its weight is
being distributed equally, and it does not tilt more than 2 degrees
in any direction.
Your warewasher should be placed in a location that allows the
electrical, supply water and waste water connections to be fitted
(
►
4.3).
When positioning your warewasher, ensure that the water inlet,
chemical tubes and drain hoses are not kinked or squashed. Care
must also be taken to ensure the warewasher does not rest on
any of its supply hoses / leads.
4.3
Site Requirements
Overall Warewasher and Clearance Dimensions
Dimensions (mm)
G350 D400 /
G400
D400
DUO /
G400
DUO
D500 /
G500
D500
DUO /
G500
DUO
Ware-
washer
A =
width
410
450
550
550
570
B =
depth
517
517
605
605
608
C =
height
(min)
644
760
830
830
830
Recess
D =
width
430
470
570
570
590
E =
depth
537
537
625
625
645
F =
height
664
780
850
850
860
20mm
10mm
B
F
E
D
A
C