MODEL 821A PWM MODEL RAILROAD THROTTLE 

 
The model 821A PWM model railroad throttle has been designed for use with any scale DC 
model railroad system. Like it’s predecessor the model 820, this throttle has been designed to 
provide unparalleled performance in both switching and mainline usage. It is easily installed and 
requires no maintenance.  Please follow these instructions for installation and modifications to 
enhance your operational enjoyment. 
 
 

INSTALLATION 

 
The model 821A needs a supply voltage source to work. The supply voltage can be 12 to 24 volts 
AC or DC. The ability to operate from DC power source makes this throttle especially attractive 
for outdoor operating situations with battery supply (eg. automotive batteries). Applying voltages 
above the recommended limits can damage the throttle. Voltages below the recommended limits 
may result in erratic or unreliable operation. The power supply must be able to supply enough 
current to allow reliable operation to your layout. A supply rated for 3 amps is recommended, 
however, you can get away with less if you don’t expect to draw the 3 amp maximum. Be warned 
though, a power supply rated for less than 3 amps can be permanently damaged if the output of 
the throttle is shorted during operation. Be sure to f

use the power supply’s output terminals to 

protect the supply. If you are unsure of how to do this consult an electrician or an electronics 
technician. Connect the supply voltage to terminals 5 and 6. 
 
If you have a common rail blocked system and plan to use more than one throttle an individual 
power supply must be used for each throttle. If you have a fully isolated blocked system (both 
rails gapped) multiple throttles can be operated from one supply source. Again, be sure the power 
supply is capable of supplying ample current to operate all of the throttles. 
 
The large aluminum heat sink can become very hot during normal operation and will become 
especially hot in the case of overloads caused by a short applied to the tracks or throttle output 
terminals. The printed circuit assembly should be mounted so that adequate air flow is available 
to help cool the heat sink.  Do not touch the heat sink unless you are sure it has not become too 
hot to touch. 
 
The printed circuit assembly can be mounted with #6 hardware at each of the four corners of the 
board. If you plan to mount the PCB on a metal surface spacers should be used in order that the 
soldered side of the circuit board clears at least ¼” above the mounting surface. 
 

ALWAYS DOUBLE CHECK YOUR CONNECTIONS TO ENSURE SAFETY !!! 

 

TRACK CONNECTIONS 

 
The throttle’s output appears at terminals 7 and 8 connect to the track. Be sure your connections 
are solid and that wires are not frayed. Use stranded 18AWG minimum insulated wire and make 
sure the insulation is not cracked or compromised in any way that will cause a short circuit.

 

 

CONTROL HANDSET CONNECTIONS 
 

Refer to figure 1 for handset connections to the printed circuit board. If you are using the 
optionally available 851HS handset follow the color code beside 

figure 1

. If you plan to construct 

your own handset follow the connections as per the diagrams included.

 