ELECTRICAL BRAKE BLEEDER 30-60L 3.5bar

7. Turn the power switch (5) to the ON position. The green light on the switch should light up.

8. Adjust the bleed pressure by turning the pressure regulator knob (9) to the pressure recommended 

by the vehicle manufacturer. Purging can now begin (refer to the vehicle manufacturer’s procedure). 

These instructions must be specifically followed when working on ABS systems.

9. Before removing the pressure hose (2) from the master cylinder adapter, reduce the pressure by 

turning off the unit (5). Replace the original master cylinder cover on the tank.

In the event that the brake/clutch pedal becomes soft or the reactivity of the brake/clutch pedal 

is too long, it is necessary to pump the pedal vigorously and repeat the bleeding procedure again.

Setting the appropriate purge pressure

The pressure is set at the factory to 1 bar. This ensures that the master cylinder tanks are not 

deformed with too much pressure. It also prevents rubber or dust seals from leaking.

If less pressure is required to purge some systems, turn the knob to reduce the pressure. In case 

a higher pressure is required, the pressure can be increased by turning the regulator knob to the 

desired pressure.

Attention!

After changing the pressure setting of the purge unit, reset it to the factory setting of 1 bar.

Pre-suction system 

The recovery canister (23) must be connected to the end cap of the rear panel.

Put the on/off switch (5) in the suction position.

Use the pipette to remove the old brake fluid from the reservoir. Clip the pipette onto the connector 

on the back panel.

Turn off the power (ON/OFF switch (5) in position 0). 

Fill with new brake fluid (as recommended by the manufacturer).

Please follow the steps in the instructions.

The pre-suction system must not be used for the transfer of other fluids!

ONLY FOR BRAKE FLUID!

Any warranty claim shall be void in the event of non-compliance with this provision.

When should the device be refilled?

After reaching a low level of liquid inside the tank, the unit automatically stops the pump motor, 

preventing any air from being pumped into the brake system.

An audible warning signal or control lamp (7) lights up as an additional control function.

In this case, the empty brake fluid reservoir must be replaced by a full reservoir. To do this, the unit 

must be switched off using the ON/OFF switch (5). Continue the procedure as described in the 

"OPerating instructions" section.

Disposal

The device must be disposed of in accordance with the legal and official provisions on waste and 

environmental protection.

Содержание HU 1103

Страница 1: ...clas com PURGEUR DE FREINS ELECTRIQUE 30 60L 3 5bar ELECTRICAL BRAKE BLEEDER 30 60L 3 5bar HU 1103...

Страница 2: ...ment sur notre site clas com Si vous avez chang d avis concernant votre achat veuillez retourner ce produit avant d essayer de l installer Before returning this product for any reason installation pro...

Страница 3: ...7 Une r paration ou une manipulation incorrecte peut entra ner des risques importants pour l utilisateur et endommager l appareil Toute utilisation involontaire ou toute utilisation incorrecte de l a...

Страница 4: ...pas endommag Les dommages dus au transport sont communiquer imm diatement l entreprise de transport concern e Description 1 Panneau de commande 2 Tuyau de remplissage 3 Raccord 4 C ble d alimentation...

Страница 5: ...eable assure la compatibilit du liquide DOT3 DOT4 DOT5 DOT6 flexible L 3 5m dimensions 920x450x560mm poids 33kg Pr conis pour Mercedes Actros Atego quip s du HPS 1 1 Placer un nouveau r servoir de liq...

Страница 6: ...les caoutchoucs ou les joints anti poussi re de fuir Dans le cas o une pression moindre est n cessaire pour purger certains syst mes tourner le bouton pour diminuer la pression Au cas o une pression p...

Страница 7: ...rt et le moins r sistant Cela emp che galement le m lange du liquide de frein r siduel encore pr sent dans le syst me Lorsque du liquide de frein clair et propre commence s couler des vis de purge ell...

Страница 8: ...ment 7 Improper repair or handling may result in significant risks to the user and damage to the unit Any unintentional use or improper use of the device will void any liability for any damage 8 A fun...

Страница 9: ...that the unit is not damaged Damage due to transport must be reported immediately to the transport company concerned Description 1 Control panel 2 Filling hose 3 Connection 4 Power supply cable 5 On o...

Страница 10: ...exible L 3 5m dimensions 920x450x560mm weight 33kg Recommended for Mercedes Actros Atego equipped with HPS 1 1 Place a new brake fluid reservoir on the fluid can support platform Then attach the chain...

Страница 11: ...knob to the desired pressure Attention After changing the pressure setting of the purge unit reset it to the factory setting of 1 bar Pre suction system The recovery canister 23 must be connected to...

Страница 12: ...ke system is completely filled it is recommended to open all vent screws at the same time The brake fluid pushes back the air in front of it This allows air to flow along the shortest and least resist...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...distributeur agr If you need components or parts please contact the reseller In case of problems please contact your authorized technician CLAS Equipements ZA de la CROUZA 73800 CHIGNIN FRANCE T l 33...

Отзывы: