HU 0607
AD BLUE FUNNEL 1,1l (VERTICAL)
PROCEDURE FOR ENTER THE CORRECTION FACTOR DIRECTLY
Carefully follow the procedure indicated below.
FORMULA
Proper correction factor = current correction factor×(actual value/ display value)
Example:
Actual value 20.75
Display value 18.96
Current correction factor 1.000
Proper correction factor 1.000×(20.75/18.96)=1.000×1.094=1.094
Wait for the meter to go standby.
Reset the resettable total.
Press the «Move» key. Keep it pressed until it
shows similar to the right image (the digit flash
in 1 zone ), which means the meter is under the
calibration mode.
Press the «Reset» key to choose the right digit
from 0 to 9.
Press the «Move» key to start the next digit.
So the digit of correction factor can be changed
one by one.
Make sure the correction factor is right, press
the «Move» key.
Keep it pressed until the indication of calibration
mode quits and the factor is saved.