V

er

. 20
131

031

Motion Sensor

Art.no 32-1627 

Model PIR-9822

Please read the entire instruction manual before using the product and save 
it for future reference. We apologise for any text or photographic errors and 
any changes of technical data. If you have any questions concerning technical 
problems please contact our Customer Service Department.

Connector block

DC12V

Connect the voltage unit’s (usually from the alarm control box, 9 to 16 V DC) 
plus cable to the connection marked “+” and the minus cable to the connection 
marked “-”.

TAMPER N.C.

“TAMPER” indicates that it is a sabotage safety switch and “N.C.” that an alarm 
goes off when the circuit is cut. If the sabotage safety switch will be used, 
the connection TAMPER shall be connected to a 24 hour N.C input on the alarm 
control box. When the detector is dismantled or destroyed the switch goes off 
and the alarm trips. 

RELAY O.P.

This output is controlled by the PIR sensor. It is normally closed (N.C) and will be 
connected to a N.C input on the alarm control box. When the detector detects 
a movement it cuts the connection. The alarm jumper (O/P SELECT) can be used 
to change the output from normally closed (N.C) to normally opened (N.O).

Jumper settings

LED ON

 

Activates the LED. Lights up with a firm light in  

 

 

the alarm position but flashes during start. 

 OFF

 

The LED is always off. Does not affect the alarm function.

PULSE NORMAL

  Standard mode for calm environments. 

 HARSH

 

Pulse controlled mode for working within 10 seconds.  

 

 

For environments with sources of interference. 

O/P SELEC.  N.C.

 

The alarm output is normally closed. 

 N.O.

 

The alarm output is normally open. 

LEDs

LED 1:

 

Turn on at detection on top channel.

LED 2:

 

Turn on at detection on bottom channel.

LED 3:

 

Lit up in alarm position. Flashes during delayed start. 

Pyro sensors

The detector is equipped with two pyro sensors for registering of moves.  

Note:

 The pyro sensors must not be touched!

Scale for vertical setting

The height of the circuit board can be adjusted by loosening the fastening screw. 
This changes the detection angle and could prevent the alarm being triggered by 
small animals.

Installation

A. Pick a spot for mounting 

• 

The detector can be mounted on a flat surface, a corner or with the included 
bracket. Make sure the detector is mounted on a solid surface. 

• 

The detector should be mounted indoors on a spot which does not have 
openings towards the outdoor environment. 

• 

Do not mount the detector in a spot where it is exposed to hot or cold air. 

• 

Avoid pointing the detector towards heating, cooling, or ventilation devices. 
Also avoid pointing it towards metal walls, curtains, fridges or other surfaces 
that may switch temperature quickly. 

• 

Avoid placing larger objects in front of the detector. It can change 
the detecting area’s surface or volume. 

• 

Pick mounting spot so the detecting range is in a 45 degrees angle towards 
a possible thief. Mounting in corners is recommended. 

• 

The mounting height should be 2 to 3 metres. 

D. Mounting the back cover

The back cover is prepared for mounting on a flat surface, a corner or with 
the included bracket. 
1.  Open a cable hole on the back cover for pulling the connection cables.
2.  The mounting holes on the back of the cover are for mounting on a plane 

surface while the holes on the sides are for mounting in corners. 

3.  Mount the detector’s back cover on the spot you have chosen. 
4.  The detector can also be mounted on the included bracket. The detector can 

then be turned to the right position for best detection. 

E. Wiring

1.  Put the circuit board back in the back cover and lock it in place with the screws. 
2.  Connect the wires to the connecting block according to fig.
3.  Put the front cover back. Make sure the sabotage safety switch is pushed in 

when the front cover is put back. 

Testing the PIR sensor

A test can be performed after the IR detector has finished its delayed start (the LED 
flashes after start) to test the detector’s area of supervision. 
1.  Let the alarm start properly (the LED changes to firm light). 
2.  In position “NORMAL” the alarm will go off when both the top and bottom 

channel react simultaneously. 

3.  In position “HARSH” it is required that both the top and bottom channel react 

twice within 10 seconds for the alarm to go off. 

4.  The detection area’s size and vertical angle is adjusted by moving the circuit 

board up or down for best reception. 

Disposal

Follow local ordinances when disposing of this product. If you are  
unsure about the disposal of this product contact your municipality.

Specifications

Power Consumption 

15 mA (at 12 V DC)

Operating Voltage 

9–16 V DC (12 V DC rated voltage)

Type of reaction 

Passive IR with changing polarity

Start up time 

Normally 2 minutes (with flashing LED)

Alarm period 

2–3 seconds

Alarm output 

N.C or N.O relay output with 10 Ohms serial  

 

 

connected resistor (nominal voltage 28 V DC, 0.1 A)

LED for test 

For top and bottom channel and alarm. In and out  

 

 

connectable alarm diode

Pulse counting 

Normal reaction or 2 pulses within 10 seconds

Sabotage safety switch 

Normally closed contact with 10 Ohms serial  

 

 

connected resistor (nominal voltage 12 V DC, 50 mA)

Operating Temperature 

-10 °C to 55 °C

Relative humidity 

95 % non condensing

EMC 

According to CE norms

Dimensions 

127 × 64 × 45 mm

1

2

3

1.  Screw
2.  Front cover
3.  Security lock

B. Remove the front cover

1.  Loosen the screw by turning it anti-clockwise
2.  Loosen the front cover by inserting the top of a screwdriver in the security lock. 
3.  The front cover will pop up and may be removed. 

C. Remove the circuit board

You need to remove the circuit board to be able to mount the back towards 
the surface. 
1.  Loosen the screws and carefully remove the circuit board from the back. 

4. Screw
5.  Backside of the back cover
6.  Swivel attachment

4

5

6

Содержание PIR-9822

Страница 1: ...s in front of the detector It can change the detecting area s surface or volume Pick mounting spot so the detecting range is in a 45 degrees angle towards a possible thief Mounting in corners is recommended The mounting height should be 2 to 3 metres D Mounting the back cover The back cover is prepared for mounting on a flat surface a corner or with the included bracket 1 Open a cable hole on the ...

Страница 2: ...områdets yta eller volym Välj monteringsplats så att avkänningsområdet är i 45 graders vinkel mot en inkräktares tänkta väg Montering i hörn rekommenderas Monteringshöjden bör vara 2 till 3 meter E Elektrisk inkoppling 1 Sätt tillbaka kretskortet i bakstycket och fixera det med fixeringsskruvarna 2 Anslut kablarna till anslutningsplinten enligt anslutningsschemat 3 Sätt tillbaka frontkåpan Se till...

Страница 3: ...lg en plass for detektoren slik at følsomhetsområdet er i 45 vinkel mot en inntrengers tenkte vei Det anbefales montering i et hjørne Monteringshøyden bør være 2 til 3 meter E Elektrisk innkobling 1 Sett kretskortet tilbake i bakstykket og fest det med skruene 2 Koble kablene til tilkoblingsplinten i henhold til koblingsskjema 3 Sett på frontdekselet igjen Påse at bryteren for sabotasjebeskyttelse...

Страница 4: ...aa tunnistusalueen alaan tai tilavuuteen Valitse asennuspaikka siten että tunnistusalue on 45 asteen kulmassa tunkeilijan ajateltua reittiä kohti On suositeltavaa asentaa laite kulmaan Asenna tunnistin 2 3 metrin korkeudelle D Takakappaleen asennus Takakappale on tarkoitettu asennettavaksi tasaiselle pinnalle kulmaan tai pakkauksen kiinnikkeen avulla 1 Avaa takakappaleeseen reikä johdolle liitäntä...

Страница 5: ...melder aufstellen Dies kann sich auf den Erfassungsbereich auswirken Einen Montageort vorsehen bei dem sich der Erfassungsbereich im 45 Grad Winkel zu dem Weg befindet den ein Eindringling nehmen könnte Die Anbringung in einer Ecke empfiehlt sich Die Montagehöhe beträgt 2 3 m D Montage des Rückteils Das Rückteil kann auf ebener Fläche oder in einer Ecke mit den mitgelieferten Befestigungselementen...

Страница 6: ... övre kanal 3 Fästskruv för kretskort 4 Bygel för lysdiod ON OFF 5 Pyrosensor för övre kanal Rör ej 6 Sabotageskyddsbrytare 7 Anslutningsplint 8 Lysdiod 3 för larm 9 Pyrosensor för undre kanal Rör ej 10 Skala för vertikal inställning 11 Bygel för pulsräkning 12 Alarmbygel N C N O Tilkoblinger 1 Lysdiode 2 for deteksjon i nedre kanal 2 Lysdiode 1 for deteksjon i øvre kanal 3 Festeskrue for kratskor...

Отзывы: