Test Data
Commission Regulation (EC) No 1275/2008 Requirement
Mode
Ecodesign requirements, from 7 January 2013
Result - Remark
Verdict
Off mode
Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W
0 W
P
Standby mode
Power consumption in ‘standby mode(s)’:
The power consumption of equipment in any
condition providing only a reactivation function,
or providing only a reactivation function and a
mere indication of enabled reactivation function,
shall not exceed 0.50 W.
N/A
The power consumption of equipment in any
condition providing only information or status
display, or providing only a combination of
reactivation function and information or status
display shall not exceed 1.00 W.
N/A
Seasonal space heating energy efficiency
Description
Value
Seasonal space heating energy efficiency in active mode-
η
S,on
40 %
For electric local space heaters-
η
th
100 %
The electric to primary energy ‘conversion coefficient-CC
2.5
F
(1) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency of electric storage local space heaters due to
adjusted contributions for options for heat storage and output; and a negative
contribution to seasonal space heating efficiency for commercial local space heaters
due to adjusted contributions for options for the heat output, expressed in %;
0.0 %
F
(2) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls of indoor
heating comfort, the values of which are mutually exclusive, cannot be added to
each other, expressed in %;
6.0 %
F
(3) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls for indoor
heating comfort the values of which can be added to each other, expressed in %;
0.0 %
F
(4) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by auxiliary electricity consumption, expressed in %;
0.0 %
F
(5) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by energy consumption of a permanent pilot flame,
expressed in %.
0.0 %
Seasonal space heating energy efficiency-
η
S
36.00 %
Verdict
P