14
E
n
g
li
s
h
E6
The water pres-
sure is not high
enough to initiate
the heating and
filtering of the
water. A warning
signal will sound.
The water in- and/or outlet on the
inside of the pool is blocked.
The filter cartridge is clogged.
The water level in the pool is
below the minimum.
There is air in the system.
The pump is out of service.
Clean the water in- and/or
outlet on the inside of
the pool.
Clean the filter cartridge.
Fill with water to above
the minimum level.
Empty the system of air
(see the Pump instructions
section above).
Contact your retailer.
E7
The pump has run
dry and therefore
overheated.
The water level has been too low. Fill the pump with water
and let the pump cool down
before starting it again.
If this does not help,
the pump must be repaired
by a qualified technician.
Resetting
1. Turn the pump off and unplug the mains lead from the wall socket.
2. Insert plugs into the inlet and outlet on the inside of the pool.
3. Disconnect the pump from the hoses.
4. Turn the pump upside down.
Find the hole marked “RESET”.
5. Carefully insert a suitable object into the hole until a sound is heard.
6. The pump has now been reset.
7. Reconnect the pump and remove the inlet and outlet plugs from inside the pool.
8. Start the pump as described previously.
Disposal
This product should be disposed of in accordance with local regulations.
If you are unsure how to proceed, contact your local authority.