12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
ANNUALLY
1. The crane should be fully inspected annually by a competent person.
2. Each load bearing bolt should be removed and inspected for wear,
deformation or cracks. If any are apparent, the bolt should be renewed.
3. Check the hydraulic ram operation and inspect for oil leaks. A slight
dampness on the ram is normal, but where leakage is apparent, the ram
seals must eventually be renewed and the lost oil be replaced. Consult
your Clarke service department.
4. Check castors to ensure they move freely without undue wear to their
spindles, and that the wheels are not cracked or damaged.
5. Remove any rust and repaint to prevent further corrosion.
6. Ensure that all decals and warning labels are in place and clearly legible.
HYDRAULIC OIL
If any leakage is observed, it may be necessary to top up the hydraulic oil
level, as follows.
1. Lower the jib to its lowest position,
and remove the bolt that joins the
ram to the jib. This will allow the
ram to fully retract.
2. Rest the ram against the main
support post and raise and prop
up the jib. Use a cable or similar, to
ensure the ram does not move.
3. Remove the filler plug from the
side of the ram.
4. Top up the oil until it is level with the hole and replace the filler plug.
NOTE:
Top up using Clarke hydraulic oil (part number 3050830).
•
Do not mix different types of oil.
Содержание Strong-Arm 7611025