background image

4

WATER CONNECTIONS

IMPORTANT

DO NOT connect the pump to the power supply until the hose/pipe

installation is completed.

Because of the variety of possible installations, no plumbing accessories are
supplied as standard with your pump.  However, accessories designed specifically
for this range of pumps are available from your CLARKE dealer and are listed on
page 6.

from  an above ground pool. However, it is possible
to draw water from a sunken pool, providing the
suction lift does not exceed the distance specified
for your pump (see Specifications on page 7).

A. SUCTION LIFT

The suction lift i.e. the vertical distance between
the water level and the pump should not exceed
the distance specified for your pump (see
Specifications on page 7).

A foot valve/filter MUST be fitted to the lower end
of the suction hose, (as illustrated in fig.2), so as to
help retain water in the suction system.
Remember.... this is NOT a self priming pump.

The pump must always be installed and
operated in a horizontal position i.e. with the
outlet port (see Fig.1), facing vertically
upwards. The fixing slots in the base should
be used as necessary to secure the pump
firmly in its operating position. Also, ensure
that there is adequate air circulation around
the motor.

Avoid situations where there is the risk of
water coming into contact with the outside
of the pump. Neither the motor or the
terminal box are intended to be waterproof.

Attach suitable 1” ID hose to the inlet port, securing with a worm drive clip. The
other end of the hose should be connected to a strainer, or foot valve/filter
depending upon the type of installation (see below), and should rest on the bottom
of the pool. Ensure all connections are air tight.

Attach also a suitable 1” ID hose to the outlet port using a worm  drive clip. The
other end of the hose should be connected to your Water Filter (available from
your Clarke dealer - see page 6).  Ensure there are no kinks in the hose.

These notes are for guidance on how to achieve a proper working system.

The schematic diagrams, figs. 3 and 4, illustrate possible methods of pipework
installation. This pump is designed primarily, to br gravity fed, that is, drawing water

Fig.1

Foot Valve/

Filter

Fig.2

Содержание SPP3

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS POND PUMP Model Nos SPP3 SPP6 0200 ...

Страница 2: ... effect your statutory rights SAFETY PRECAUTIONS 1 Ensure the pump is installed in a horizontal position with the outlet facing vertically upwards and that it is firmly anchored via its fixing screws 2 Ensure there is an adequate air flow around the pump DO NOT mount it in an enclosed atmosphere 3 Ensure all water pipes supply or discharge are adequately supported where necessary so as not to put ...

Страница 3: ...l marked with N or coloured BLACK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewirable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is subsequently inserted into a socket outlet 2 Never use the plug without the fuse cover fitted 3 Should you wish to replace a detachable fuse c...

Страница 4: ...sition i e with the outlet port see Fig 1 facing vertically upwards The fixing slots in the base should be used as necessary to secure the pump firmly in its operating position Also ensure that there is adequate air circulation around the motor Avoid situations where there is the risk of water coming into contact with the outside of the pump Neither the motor or the terminal box are intended to be...

Страница 5: ... Clarke International Service Department for advice B GRAVITY FEED Do not place any restriction on the inlet side of the pump The delivery head i e the vertical distance between the pump outlet and the point of discharge should not exceed distance specified for your pump see Specifications page 7 To prevent unnecessary strain or possible distortion to the pump ensure that adequate support is provi...

Страница 6: ... 2 Check to see that no foreign matter is fouling the intake system check the strainer is not blocked or obstructed Should you still experience problems then contact your Clarke dealer or CLARKE International Service Department for advice Please contact your nearest dealer or CLARKE International on one of the following numbers PARTS SERVICE TEL 020 8988 7400 PARTS SERVICE FAX 020 8558 3622 or e m...

Страница 7: ... Max Output 60 L min 3 6M3 h 100 L min 6M3 h Insulation Rating IP44 IP44 Dimensions LxWxH 255x150x190mm 255x150x190mm Part No 7175010 7175020 NOTE As the pumping head is increased so the flow rate of water will decrease Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications a...

Страница 8: ...PARTS DIAGRAM 8 ...

Страница 9: ...P1240012 6 Sealing ring LDP1200027 7 Gasket LDS3500199 8 Terminal box LDS3500214 9 Capacitor LDP1360009 10 Screw LDP1100004 11 Seal LDP1200021 12 Screw LDP1100006 13 Cover LDP3500218 14 Screw LDP1100006 15 Washer LDP1120003 16 Cable clamp LDP1510004 17 Switch assembly LDP1380001 18 Power Cable LDP1330013 19 Nut LDP1510009 20 Cable Gland LDP1230001 21 Motor Assembly n a 9 ...

Отзывы: