background image

4

Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]

ELECTRICAL CONNECTIONS

WARNING!  Read  these electrical safety instructions thoroughly
before connecting the product to the mains supply.

Before switching the product on, make sure that the voltage of your
electricity supply is the same as that indicated on the rating plate. This
product is designed to operate on 230VAC 50Hz. Connecting it to any other
power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to
change the fuse in the plug, the fuse cover must be refitted. If the fuse cover
becomes lost or damaged, the plug must not be used until a suitable
replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or
due to damage, it should be cut off and a replacement fitted, following the
wiring instructions shown below. The old plug must be disposed of safely, as
insertion into a mains socket could cause an electrical hazard.

WARNING! The wires in the power cable of this product are
coloured  in accordance with the following code:

Blue = Neutral          Brown = Live

Yellow & Green = Earth

If the colours of the wires in the power cable of this product do not
correspond with the terminal markings of your plug, proceed as follows:

The wire which is coloured Blue must be connected to the terminal
which is marked N or coloured Black

.

The wire which is coloured Brown must be connected to the
terminal which is marked L or coloured Red.

• The wire which is coloured Yellow & Green  must be connected to

the terminal which is marked E or      or coloured Green

.

Plug must be BS1363/A approved

Earth

Always fit a 13 Amp fuse.

(Green and Yellow)

Neutral

Live

 (Blue)

        (Brown)

Ensure that the outer sheath of the cable is firmly held by the clamp

Always connect this product to the mains supply via a Residual Current
Device (RCD)

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs
yourself.

Содержание SPP10 7175030

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC12 11 1HP SWIMMING POOL PUMP Model SPP10 Part No 7175030 ...

Страница 2: ...ion and the use of a non return valve will facilitate immediate priming The pump inlet is higher than the impeller inlet so that it can start operating when only the pump body is filled with water Upon receipt any damage or deficiency should be reported to your CLARKE dealer immediately CONTENTS 1 x Swimming Pool Pump c w integral Pre filter Basket 2 x Inlet Outlet Connectors 2 x Inlet Outlet Conn...

Страница 3: ...ear 6 ALWAYS maintain the pump with care and keep it clean for best safest performance 7 NEVER use this product if any part is damaged Have it inspected and repaired by your local Clarke dealer Always turn the pump off before carrying out any maintenance 8 NEVER modify this pump in any way Use it ONLY for the purpose for which it is designed 9 NEVER use for pumping flammable liquids or corrosive c...

Страница 4: ...iring instructions shown below The old plug must be disposed of safely as insertion into a mains socket could cause an electrical hazard WARNING The wires in the power cable of this product are coloured in accordance with the following code Blue Neutral Brown Live Yellow Green Earth If the colours of the wires in the power cable of this product do not correspond with the terminal markings of your ...

Страница 5: ...TION OF THE PUMP A typical installation of the pump is shown in Fig 1 The pump must always be installed and operated in a horizontal position i e with the outlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in it s operating position Mount the pump on raised blocks or a purpose built platform to protect it from flooding Always ensure there is...

Страница 6: ...the use of suitable 50 mm I D hose secured with a worm drive clip Ensure all connections are air tight Tighten them enough to secure the hose during pressurised operation but not so tight as to crack the plastic inlet outlet connectors Where the pump is to be a permanent fixture vibration and strain on adjacent parts can be reduced by the insertion of a short flexible section of hose between any r...

Страница 7: ...ming process and it is suggested that a non return valve be fitted to the end of the suction pipe 5 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor may be damaged If a leak is noticed at this point it may indicate that the seal is worn and therefore in need of replacement Contact your CLARKE dealer or ...

Страница 8: ...has been used with contaminated or salty water it should be thoroughly flushed with clean water following use both inside and out It should then be drained before replacing the drain plug and covered over if not already installed in a clean dry environment sheltered from the weather Remember to re prime the pump when returning to service In the event that dismantling and overhaul of the pump is ne...

Страница 9: ...k s a b r e t l i f n a e l c d n a k c e h C e d i s n i l a i r e t a m d e t s e g n o C p m u p t e k s a b r e t l i f t u o n a e l C p m u p h s u l f k c a b e n i l y r e v i l e d r o n o i t c u S d e t c u r t s b o e r u s n e d n a n o i t c u r t s b o e v o m e R e n i l y r e v i l e d n i s k n i k o n e r a e r e h t e g a k a e l e p i p t e l n I r o t c e n n o c d n a e p i ...

Страница 10: ...p i p t e l n i n i e c n a t s i s e R y b d e s u a c n o i t c u r t s b o s a t u o n a e l c d n a e p i p k c e h C y r a s s e c e n t n e n o p m o c g n i t a t o r e s o o L r o f r e l a e d r u o y o t n r u t e R s r i a p e r s i p m u p f o n o i t a l l a t s n I e l b a t s n u n o i t i s o p e r d n a p m u p p o t S r o p m u p n i t e k c o p r i A e n i l e p i p r e l l e p ...

Страница 11: ... e p y T e v l a V n r u t e R t e l t u o t a e p y t p a l F e z i S t e l t u O t e l n I m m d o 6 5 d i 0 5 y l p p u S r e w o P z H 0 5 V 0 4 2 0 2 2 r e w o P t u p t u O W 0 5 7 P H 1 l e v e L e r u s s e r P d n u o S A p L B d 8 8 6 l e v e L r e w o P d n u o S A w L B d 3 5 7 r e w o P d n u o S d e e t n a r a u G A w L B d 8 7 e p y t p m u P l a g u f i r t n e C Please note that ...

Страница 12: ... r e h s a W 4 1 0 1 P P S G Z 8 5 4 w e r c S e n i h c a M d H X 5 4 0 1 P P S G Z 6 5 1 r e h s a W e v a W 5 1 0 1 P P S G Z 2 1 6 4 x o B r o t i c a p a C 6 4 0 1 P P S G Z 1 6 1 t l o B x e H 6 1 0 1 P P S G Z 8 7 4 t e k s a G 7 4 0 1 P P S G Z 1 7 1 d n a l G f o o r p r e t a W 7 1 0 1 P P S G Z 1 8 4 r o t a t S r o t o M 8 4 0 1 P P S G Z 1 8 1 t r o p p u S p m u P 8 1 0 1 P P S G Z 1...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 16: ......

Отзывы: