OPERATING INSTRUCTIONS
Figure 11
Switching the air compressor OFF
To switch the air compressor off,
1
Close the outlet tap and press down on the on/off button (red button).
2
Switch off the mains supply and remove the plug.
•
You should never leave the compressor air reservoir unattended while
under pressure.
•
Always release the pressure from the resevoir when not in use or prior to
storage, as described in 'draining the reservoir' on page 16.
Removing a tool from the air hose
Warning!
Always set the pressure regulator to zero before attempting to remove or
replace a tool.
1
Press down on the on/off button (red button) located on top of the
pressure regulator.
2
Close the air outlet tap and trigger the tool (spraygun, air tools etc), to
release air from the air hose BEFORE disconnecting the hose from the
compressor.
Reset button
This compressor is equipped with a thermal
overload device.
When the motor overheats for any reason,
the overload device automatically cuts
the power thereby preventing damage to
the motor.
Wait around 5 minutes for the motor to
cool and press the reset button. See figure
11.
If you restart the compressor and the
overload cutout activates again, switch
off the compressor, remove the plug from
the mains and have your compressor
checked by a qualified service agent.