PROBABLE CAUSE

REMEDY

The compressor 
has stopped and 
does not start.

Bad electrical connections.

1.

Check electrical connections.

2.

Clean and tighten if necessary. 

Overload cutout switch has 
tripped.

1.

Switch off and wait approx 5 
minutes.

2.

Press the reset button and 
switch on again.

Motor windings burnt out.

1.

Contact your Clarke dealer for 
a replacement motor.

The compressor 
does not reach 
the set pressure 
and overheats 
easily.

Compressor head gasket 
blown or valve broken.

1.

Return the machine to your 
nearest service agent.

Compressor does 
not start.

The reservoir has already fully 
pressurised.

1.

Open drain valve to expel air. 
Compressor should start again 
when pressure reduces.

Air leaking from 
the non-return 
valve when the 
compressor is not 
running.

Faulty non-return valve.

1.

Drain receiver completely of 
air. 

2.

Remove the valve end plug, 

3.

Carefully clean the valve seat 
and the gasket

4.

Reassemble.

Air pressure from 
the regulator will 
not adjust.

The diaphragm within the 
regulator body is broken. 

1.

Replace regulator

The compressor is 
very noisy and 
makes a metallic 
knocking sound.

Compressor damaged and 
needs overhaul.

1.

Return the machine to your 
nearest service agent.

Содержание Raider 15/500

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS1212 50L AIR COMPRESSOR MODEL NO RAIDER 15 500 PART NO 2242200...

Страница 2: ...ate of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for t...

Страница 3: ...the recommended setting for the tool 10 When spraying flammable materials e g cellulose paint ensure that there is sufficient airflow and keep clear of any source of ignition 11 Before spraying any m...

Страница 4: ...connected to the terminal which is marked N or coloured back The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the termi...

Страница 5: ...E WHEELS Use a spanner to attach the wheels to the compressor Use the washers and spring washer in the positions shown ATTACH THE SUPPORT FEET Insert the support feet into the position shown FIT THE A...

Страница 6: ...CAP 1 Remove the travel plug 2 Insert the oil filler cap MOVING THE AIR COMPRESSOR Stop the compressor and disconnect it from the power supply before you move it Always use the handle To prevent dama...

Страница 7: ...ON OFF switch to the OFF position pushed down Make sure that the compressor is on level ground Make sure that the supply voltage matches the voltage shown on the data label CHECK THE OIL LEVEL 1 Make...

Страница 8: ...he air hose 3 Turn the outlet valve handle to the on position NOTE The outlet valve is shown without the air hose fitted for clarity TURNING THE COMPRESSOR ON 1 Plug the compressor into the power supp...

Страница 9: ...ent SET THE OUTLET PRESSURE When viewed from the front the left hand outlet valve is adjustable The right hand outlet valve will only supply the full reservoir pressure and is not adjustable 1 Use the...

Страница 10: ...e the air hose 4 Disconnect the tool from the hose TURNING THE COMPRESSOR OFF 1 Follow steps 1 3 in Removing Tools From The Air Hose above 2 Disconnect the compressor from the power supply 3 Slowly op...

Страница 11: ...fully drained RESET BUTTON This compressor has a thermal overload device If the motor gets too hot the thermal overload device cuts the power which prevents damage to the motor If the thermal overloa...

Страница 12: ...be examined monthly more often in dusty conditions 1 Remove the filter from the compressor 2 Remove the filter cover from the filter 3 Remove the filter from the filter cover 4 Clean the sponge and th...

Страница 13: ...or is switched OFF and disconnected from the power supply 2 Examine the non return valve and replace the gasket and valve if necessary SPECIFICATIONS Max Pressure 8 Bar Voltage 230 VAC 50 60Hz Air Dis...

Страница 14: ...compressor does not reach the set pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest service agent Compressor does not start The reservoir...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM...

Страница 16: ...r HTRAI1550037 38 Reset button HTRAI1550038 39 Bolt M4x6 HTRAI1550039 40 Junction Box HTRAI1550040 41 Stator HTRAI1550041 42 Rotor HTRAI1550042 43 Bearing 6202 HTRAI1550043 44 Wave Washer D35 HTRAI155...

Страница 17: ...17 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com POPULAR ACCESSORIES...

Страница 20: ......

Отзывы: