background image

5

Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]

PREPARATION FOR USE

FITTING THE BATTERIES

1. Unscrew the battery cap.

2. Install batteries (2 x CR2032 as supplied) with their marked faces outwards,

and screw the cap back on.

If the batteries are in poor condition the          icon will flash during
operation and new ones should be fitted.

Typical life of the batteries is 60 hours continuous use.

SWITCHING ON & OFF

1. Press the 

       

button to turn the wrench on.

The LCD panel will display all characters and after 2 seconds the display
will show 0.00.

The wrench will be in 

‘TRACK’ 

mode, i.e., it will measure and display the

actual torque detected.

3. To manually turn the wrench off, press and release the         button.

If you do not use the wrench for 3-4 minutes it will turn off automatically.

4. Never turn the wrench off while force is applied.

DISPLAY LIGHTING

1. Press the button

             

for the display lighting to come on.

2. Press again to turn the lighting off.

HOW TO SET ‘TRACK’ OR ‘PEAK’

1. Press and release the

 M/u 

button to exit 

peak,

 if 

track

 is preferred.

The display can alternate between 

peak 

and

 track 

(track is the default

mode and is not displayed.

HOW TO SELECT THE UNIT OF MEASUREMENT’

1. Press and hold the 

M/u 

button for 2 secs.

The display will scroll quickly through the available units of measurement.
(N.m, lbs-in, lbf.ft and Kgf.m).

2. Release the 

M/u 

button when your required unit is shown.

Содержание PRO235

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC012 11 1 4 DRIVE DIGITAL TORQUE WRENCH Model No PRO235 PART NO 1700635 ...

Страница 2: ...can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL PROTECTION Do not dispose of this product with general household waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of appropriately according to the laws govern ing Waste Electrical and Electronic Equipment at a recognised dis posal fac...

Страница 3: ...e t t a B r H 0 6 e r u t a r e p m e T g n i t a r e p O 0 4 0 O C Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications at any time without prior notice OVERVIEW This torque wrench is designed to tighten nuts with precision and with careful and considerate use the wrench w...

Страница 4: ...ured preset value displayed C Selectable units of measurement D Battery Condition indicator THE PUSHBUTTONS 1 2 3 6 5 4 1 Warning LED illuminates when pre set torque is reached 2 M u button for measurement unit selection and to select between Track and Peak modes 3 Zero tare 4 Change the value of the pre set torque 5 lluminating the display press to move to the next digit 6 Power ON OFF button ...

Страница 5: ... TRACK mode i e it will measure and display the actual torque detected 3 To manually turn the wrench off press and release the button If you do not use the wrench for 3 4 minutes it will turn off automatically 4 Never turn the wrench off while force is applied DISPLAY LIGHTING 1 Press the button for the display lighting to come on 2 Press again to turn the lighting off HOW TO SET TRACK OR PEAK 1 P...

Страница 6: ...an even pressure throughout the operation As the target torque setting is approached the LED will flash and the alarm will bleep before a continuous tone and light when the target torque is reached or exceeded If in PEAK mode the red LED will light up and the alarm will bleep when the target torque is reached and the highest measured reading will be displayed and stored Press the to clear this rea...

Страница 7: ...he batteries to avoid the risk of leaking 3 Clean by wiping the tool and the display with a soft cloth Never immerse it in water or any type of solvent or cleaning fluid MAINTENANCE CALIBRATION The wrench has been calibrated at the factory order to ensure accurate readings and should not require any re calibration The original calibration certificate should be supplied If inaccuracy is suspected c...

Страница 8: ......

Отзывы: