background image

7

SERVICING & STORAGE

1.

TURN OFF THE COMPRESSOR WHEN NOT IN USE: 

When not in use, turn off

the compressor by depressing the On/Off switch, remove the plug from
the mains supply. Slowly undo the drain valve to release the pressure from
the reservoir. Close the drain valve before storage and ensure it is fully
tightened before use.

2.

MOVING THE COMPRESSOR: 

Always transport the compressor by lifting or

pulling it with the handle.

3.

CLEANLINESS AND CONDITION OF THE COMPRESSOR: 

Keep the external

surfaces of the reservoir clean. Avoid impact damage and do not allow
the reservoir to come into contact with abrasive or corrosive materials.

4.

DO NOT WIPE THE PLASTIC PARTS WITH SOLVENT: 

Do not use solvents or

thinners such as petrol, benzene, carbon tetrachloride or alcohol to clean
the compressor, as these chemicals will damage the finish. With the
machine unplugged from the power supply, use a dry cloth to wipe over
the plastic casing.

5.

STORE THE COMPRESSOR PROPERLY: 

When not in use the compressor

should be stored in a secure, dry place out of the reach of children.
Always lock the storage area. DO NOT leave it exposed to the elements
and avoid direct sunlight, direct heat, rain/moisture etc.

6.

ONLY USE PARTS AND ACCESSORIES RECOMMENDED IN THIS MANUAL:

 The

use of unauthorised accessories or attachments is not permitted and may
result in personal injury or damage to the compressor. Do not attempt to
repair or modify the compressor.

Содержание PIONEER 220

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS GC0511 AIR COMPRESSOR Model No PIONEER 220 Part Nos 2320220 230V 2320221 110V...

Страница 2: ...duct is found to have been abused or tampered with in any way or not used for its intended purpose Faulty goods should be returned to their place of purchase no product can be returned to us without p...

Страница 3: ...ernational reserve the right to change specifications at any time without prior notice e r u t a e F n o i t a c i f i c e p S t h g i e W g k 2 2 m m H x W x L s n o i s n e m i D 0 3 6 x 0 2 3 x 5 9...

Страница 4: ...EVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unexpected situations 5 NEVER attempt any complex repairs yourself If you have a technic...

Страница 5: ...IRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjunction with the compressor have a safe working pressure exceeding that of the machine 2 ALWAYS keep the air hose away from any a...

Страница 6: ...ired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free from dust Wipe regul...

Страница 7: ...rrosive materials 4 DO NOT WIPE THE PLASTIC PARTS WITH SOLVENT Do not use solvents or thinners such as petrol benzene carbon tetrachloride or alcohol to clean the compressor as these chemicals will da...

Страница 8: ...ue to damage it should be cut off and a replacement fitted following the wiring instructions shown below The old plug must be disposed of safely as insertion into a mains socket could cause an electri...

Страница 9: ...LY IN THE EVENT OF A POWER CUT AND SUBSEQUENT RESET DO NOT CARRY THE COMPRESSOR WHILE IT IS CONNECTED TO THE POWER SOURCE OR WHEN THE TANK IS FILLED WITH COMPRESSED AIR THIS COMPRESSOR INCORPORATES SU...

Страница 10: ...10 OVERVIEW...

Страница 11: ...place a strain on the airline fittings or hoses Take care when moving the compressor to avoid damaging the valves or fittings Always ensure it is switched off and disconnect from the mains power suppl...

Страница 12: ...er compressed air is DANGEROUS WARNING Before connecting any air tool make sure you have read and fully understood the manufacturer s instruction booklet for the air tool being used Also ensure that t...

Страница 13: ...R 1 Pull the ON OFF switch UP to start the compressor as shown in Fig 4 The motor should start immediately and run while the tank reservoir is being pressurised 2 When starting the compressor for the...

Страница 14: ...cap of the regulator towards you 2 Turn the pressure regulator knob clockwise to increase pressure and anticlockwise to decrease pressure The pressure setting will be displayed by the outlet pressure...

Страница 15: ...shut off the compressor Never stop the compressor by unplugging it from the power supply It should be turned off as above 2 After use set the outlet pressure back to zero 3 Operate the trigger of all...

Страница 16: ...ilter element shown in Fig 8 for cleanliness If necessary it may be gently washed in warm soapy water Rinse and allow to dry thoroughly before refitting This should be done more frequently if the comp...

Страница 17: ...2 YEARS Check the non return valve and if necessary replace the gasket O ring shown in Fig 11 IMPORTANT The use of parts other than Clarke replacement parts may result in safety hazards poor performa...

Страница 18: ...a g n i t t e s e h t s e h c a e r e r u s s e r p l o r t n o c e r u s s e r p e h t f o i s p 5 9 x o r p p a h c t i w s e h t m o r f g n i k a e l d n u o f r i A e v l a v h c t i w s e r u s...

Страница 19: ...L 0 0 0 1 5 7 1 1 0 N F 1 6 E V L A V N R U T E R N O N 0 0 0 2 9 0 7 4 3 N F 1 1 2 E G U A G E R U S S E R P 0 0 0 6 0 0 0 3 3 N F 2 7 T E K S A G 0 0 0 7 5 3 9 9 F N F 1 2 2 G N I L P U O C T I F K...

Страница 20: ...20 PARTS DIAGRAM AIR RECEIVER CONTROLS...

Страница 21: ...21 PARTS DIAGRAM COMPRESSOR...

Страница 22: ...1 1 T U N 0 1 0 0 9 1 1 6 1 N F 3 3 3 T E K S A G D A E H 4 1 0 0 2 1 6 1 1 N F 1 2 1 T U N 8 1 0 3 0 0 4 1 0 N F 2 4 3 E T A L P E V L A V 0 0 1 0 2 1 6 1 1 N F 1 3 1 R O T I C A P A C 4 0 0 0 0 2 9...

Страница 23: ...23 DECLARATION OF CONFORMITY...

Страница 24: ......

Отзывы: