16
TROUBLESHOOTING
If the following does not solve your problem, please contact the CLARKE service
department. See page 15
.
PROBLEM
CAUSE
SOLUTION
The pump turns
but does not
reach the
required pressure.
The pump is sucking in air
Check that all pipes and hoses are
secure
Worn out valves
Replace the valves
Worn out nozzle
Replace the water nozzle
Worn out gaskets
Replace the gaskets
Blocked/dirty water filter
Clean the water filter
Pressure
fluctuates
Worn out suction and/or
delivery valves
Replace the valves
Foreign body caught in the
valve
Check the valve and clean if needed
Air being sucked in
Check that all pipes and hoses are
secure
Worn out gaskets
Replace the gaskets
Pressure drops
Worn out suction and/or
delivery valves
Replace the valves
Foreign body caught in the
valve
Check the valve and clean if needed
Air being sucked in
Check that all pipes and hoses are
secure
Worn out gaskets
Replace the gaskets
Worn out water nozzle
Replace the nozzle
Water leaks from
the piston head
Worn out piston
Replace the piston
Casing side seal rings worn
out
Replace the seal rings
Worn out or dirty valves
Replace the valves
Insufficient water
temperature
Scale build up on the
heating coil
Clean (See page 13)
Soot build up may be
blocking the boiler
Clean
Worn out nozzle
Replace the water nozzle