If the power cable becomes damaged, IT MUST BE REPLACED, DO NOT REPAIR.
Return the pump to your Clarke dealer, or contact Clarke Service Department on:

020 8988 7400

IMPORTANT:

If you are in any doubt regarding electrical installation, you should consult a

qualified electrician. DO NOT attempt any electrical repairs yourself.

PUMP FEATURES

The pump is of rugged and durable construction, designed for long lasting
continuous operation and its’ stainless steel body provides good anticorrosive
properties. The motor is provided with built in overload protection.

For your information, the chart on page 9 shows the flow rate for the pump at
various heads. (HEAD is the distance, or height, from the surface of the water to
the point of discharge)

The pump is designed to pump water containing solids in suspension with a
maximum diameter of 50mm .

It is NOT designed for permanent installation in fish ponds or any water containing
chemicals or other acidic contaminants including salt water.

Whenever the pump is used to pump contaminated water, e.g. to drain septic
tanks, fish ponds etc., you must ALWAYS immerse the pump in clean water and
run it for a few minutes on completion to ensure it is completely cleansed of all
contaminants.

The maximum depth to which the pump should be submerged is 7.4 metres and
it will deliver water to a max. head of  7.4 metres

The pump is fitted with a Float Switch and is suitable for permanent or semi-
permanent installations, e.g. installations where it is necessary to maintain a water
at a particular level.

As the water level rises, so will the float. At a certain point the switch will operate
and start the pump. As the water level falls, so will the float until the switch operates
again and stops the pump.

Float switches are adjusted at the factory to provide the correct ON-OFF switching
mode, however, you can adjust the level at which the pump cuts in and out by
sliding the float switch cable through the clip attached to the main body. Shorten
or lengthen it as the case may be. The shorter it is, the earlier the pump will cut
out, and the water therefore will be deeper at this point. Similarly, it will cut in
earlier and the water will therefore be shallower when it does so.

It should not normally be necessary to change the length of cable (from the
clamp to the float switch), but should you do so, remember that the cable length
should NEVER be so long that the float switch fails to operate and switch the
pump OFF. ALWAYS check its operation before use.

Similarly, the cable length must not be so long so as to allow the water level to
drop below the level of the outlet pipe.

Содержание ISP11A

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS Model ISP11A SUBMERSIBLE WATER PUMP 0308 SUBMERSIBLE WATER PUMP Model ISP11A ...

Страница 2: ...d for that of others around you and will also help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faults in manufacture for 12 months from purchase date Keep your receipt as proof of purchase This guarantee is invalid if the product has been abused or tampered with in any way or not used for the purpose for which it is intended The reason for ...

Страница 3: ... be removed from the water and stored in a frost free location 10 If the pump is to be used where there may be silt or mud e g garden ponds ALWAYS keep the pump clear of any sediment by standing it on a platform or bricks or suspending from a rope or chain attached to the handle 11 DO NOT use for permanent installation in pumping clean or pure water particularly drinking water as there is the remo...

Страница 4: ...of this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN YELLOW Connect BROWN cord to terminal marked with a letter L or coloured RED Connect BLUE cord to terminal marked with a letter N or coloured BLACK FUSE RATING The fuse in t...

Страница 5: ... of all contaminants The maximum depth to which the pump should be submerged is 7 4 metres and it will deliver water to a max head of 7 4 metres The pump is fitted with a Float Switch and is suitable for permanent or semi permanent installations e g installations where it is necessary to maintain a water at a particular level As the water level rises so will the float At a certain point the switch...

Страница 6: ...ilar and ensure that this type of support is not likely to shift The pump should be well clear of silt mud or any type of marine growth IMPORTANT ALWAYS raise and lower the pump using a rope attached to the lifting handle NEVER by the power cable 6 Ensure the sump or bore hole has adequate dimensions so as not to restrict the movement of the float switch see fig 1 for recommended minimum size The ...

Страница 7: ...y Switch the pump OFF and disconnect from the mains supply Check for blockages and allow the motor to cool at least 15 minutes before attempting to restart Do not attempt to repair the pump yourself as you may damage the seals and invalidate your guarantee Repairs must be carried out by a qualified pump engineer your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 If the pu...

Страница 8: ... fails to start consult your CLARKE dealer for advice B PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked clean as necessary 2 Discharge tube clogged or obstructed clear as necessary 3 The head may be too great i e you are trying to lift the water too great a distance for the pump to cope with See specifications pages 9 4 Impeller may be damaged Consult your CLARKE dealer C PU...

Страница 9: ...33 l min Max Water Temperature 50 C Weight unpacked 11 7kg Cable Length 10m Part No 7230091 Fig 2 WARNING Connection to the mains supply MUST be made well clear of the water or if in close proximity it must be completely waterproofed and secured to prevent the possibility of it coming into contact with water If necessary consult a qualified technician A 203mm B 170mm C 2 BSP D 172mm E 98mm H 492mm...

Страница 10: ...BR00004134 10 Cables Cover DABR00004135 3 Front Bearing DABR00004129 11 Cover DABR00004137 4 Motor Shaft DABR00004126 12 Nuts and Bolts DABR00004128 5 Rear Bearing DABR00004130 13 Motor DABR00004191 6 Pump Body DABR00004125 14 Capacitor DABR00004140 7 Impeller DABR00004131 15 Cable DABR00004139 8 Seal Disk DABR00004192 16 Float DABR00004138 ...

Страница 11: ... or CLARKE International on one of the following numbers PARTS SERVICE TEL 020 8988 7400 PARTS SERVICE FAX 020 8558 3622 or e mail as follows PARTS parts clarkeinternational com SERVICE service clarkeinternational com Declaration of Conformity Parts Servicing ...

Страница 12: ......