you may damage the waterproof seal and invalidate your
guarantee. Repairs must be carried out by your CLARKE
dealer, or contact the CLARKE Service Dep’t, on 0181
556 4443.

If using this pump to pump out a garden pond,
please note that there is a small quantity of oil in
the pump seal. If the pump or seal is damaged,
possibly caused by running the pump dry,  oil
may leak out, and appear as a film on the
surface of the water. Although harmless to
people, the oil must be cleared to prevent
any possible harm to pond life. Disconnect
the pump from the electrical supply,
remove it from the pond, and clear the
oil, then contact your CLARKE dealer for
advice.

PARTS LIST & DIAGRAM

HSE 200 & HSE 400 Series

6

Item Description

Part No.

HSE 120

HSE 120A

HSE 240

HSE 240A HSE 250A

1 Strainer

HG12001

HG120A01

HG24001

HG240A01

HG250A01

2 Centrifugal Switch

HG12002

HG120A02

HG24002

HG240A02

HG250A02

3 Pump Housing

HG12003

HG120A03

HG24003

HG240A03

HG250A03

4 Impeller

HG12004

HG120A04

HG24004

HG240A04

HG250A04

5 Lip Seal

HG12005

HG120A05

HG24005

HG240A05

HG250A05

6 Mechanical Seal

HG12006

HG120A06

HG24006

HG240A06

HG250A06

7 Oil Chamber

HG12007

HG120A07

HG24007

HG240A07

HG250A07

8 Bottom Motor Plate

HG12008

HG120A08

HG24008

HG240A08

HG250A08

9 Lower Bearing

HG12009

HG120A09

HG24009

HG240A09

HG250A09

10 ‘O’ Ring

HG12010

HG120A10

HG24010

HG240A10

HG250A10

11 Rotor Shaft

HG12011

HG120A11

HG24011

HG240A11

HG250A11

12 Stator

HG12012

HG120A12

HG24012

HG240A12

HG250A12

13 Motor Case

HG12013

HG120A13

HG24013

HG240A13

HG250A13

14 Overload Protector

HG12014

HG120A14

HG24014

HG240A14

HG250A14

15 ‘O’ Ring

HG12015

HG120A15

HG24015

HG240A15

HG250A15

16 Upper Bearing

HG12016

HG120A16

HG24016

HG240A16

HG250A16

17 Capacitor

HG12017

HG120A17

HG24017

HG240A17

HG250A17

18 Upper Cover

HG12018

HG120A18

HG24018

HG240A18

HG250A18

19 Handle

HG12019

HG120A19

HG24019

HG240A19

HG250A19

20 Gland Cover

HG12020

HG120A20

HG24020

HG240A20

HG250A20

21 Cable Gland

HG12021

HG120A21

HG24021

HG240A21

HG250A21

22 Power Cable

HG12022

HG120A22

HG24022

HG240A22

HG250A22

23 Discharge Outlet

HG12023

HG120A23

HG24023

HG240A23

HG250A23

3

ELECTRICAL CONNECTIONS

All models 

EXCEPT  HSE 250A

, should have their mains lead connected to a standard

230Volt (50Hz) electrical supply through an approved plug or a suitably fused
isolator switch. We recommend that these pumps be fitted with a Residual Current
Device (RCD).

NOTE: This is mandatory when pump is used for pumping swimming pools.

Model HSE250A 

must 

be connected to a protected 110V supply, through a suitably

approved connector. On no account must a 230V, 13amp (BS1363) plug be used.

NOTE:

  If a portable 110V transformer is used, make sure it has a rated capacity

sufficient to take the load of the pump.

In the event that the pump is hard wired into the electrical system, it must be
carried out in accordance with IEE regulations.

If used for draining swimming pools or ponds, the pump MUST be fitted with a
Residual Current Device (RCD), with a rated residual operating current of no
greater than 30mA.

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT:

 The wires in the mains lead are coloured in accordance with the

following code:

Green & Yellow

-

Earth

      Blue

-

Neutral

   Brown

-

Live

As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:

Connect GREEN & YELLOW coloured cord to plug terminal marked with a

letter “E” or Earth symbol “    “ or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked with a letter “L” or coloured RED

Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK

The fuse in the plug for this appliance must be rated at 

13 amps

.

If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.
non-rewirable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a

danger ofelectric shock if it is subsequently inserted into a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most

electrical

5.

The fuse in the plug must be replaced with one of the same rating (

13 amps

)

and this replacement must be ASTA approved to BS1362.

IMPORTANT: If in doubt, consult a qualified electrician.