Thank you for purchasing this Clarke HSE Submersible Pump.

These highly efficient pumps are designed for pumping clean water, or water
containing sand or solids in suspension, depending upon the model (please see
below), and are ideally suited for draining ponds, pools, building excavations
etc.Water temperature must not

 exceed 35 C.

Before attempting to operate your pump, please read this instruction manual
thoroughly and follow all directions carefully. This is for your own  safety and that
of others around you, and to help you achieve long and trouble free service from
your pump.

GUARANTEE

This product is guaranteed against faults in manufacture for 12 months from
purchase date. Keep your receipt as proof of purchase.This guarantee is invalid if
the product has been abused or tampered with in any way, or not used for the
purpose for which it is intended. The reason for return must be clearly stated. This
guarantee does not affect your statutory rights.

SAFETY PRECAUTIONS

1.

These pumps are designed to pump WATER ONLY. Never use for pumping
flammable liquids or chemicals.

2.

Never run the pump dry

3.

An approved Residual Current Device (RCD) 

must

 be used when pumping

from ponds or swimming pools.

4.

Your submersible pump may 

only

 be used for pumping water from a swim

ming pool when there is no person or animal in the pool.

5.

Always disconnect the pump from the electrical supply before placing it
into, or removing it from the water, and before any cleaning or maintenance
of the pump.

6.

Always use the moulded handle, with a rope or cord attached if necessary,
when lifting the pump. Do not lift the pump by the mains cable, or, where
fitted, the float switch cables.

7.

DO NOT run the pump with the body exposed for longer than 10 minutes.

8.

DO NOT install the pump on sand, or ground which is likely to shift.

9.

Do not use the pump if the water is liable to freeze, as this can cause dam
age to the pump. Remove the pump from the water and store it in a frost
free location.

10. If the pump is to be used where there may be silt or mud (for example,

garden ponds), keep the pump clear of any sediment by standing it on a
platform or brick.

11. Always disconnect the pump from the mains supply before placing it into or

removing it from water, and before any cleaning or maintenance of the
pump.

2

HSEC 400A

7

1

Strainer

HG400A01

2

Strainer Packing

HG400A02

3

Impeller

HG400A13

4

Pump Casing

HG400A04

5

Oil Seal

HG400A05

6

Oil Cover

HG400A06

7

Oil Cover Packing

HG400A07

8

Mechanical Seal

HG400A08

9

Motor Casing Pkg

HG400A09

10

Lower Bearing

HG400A10

11

Motor Casing

HG400A11

12

Rotor Shaft

HG400A12

13

Stator Coil

HG400A13

14

Centrifugal Switch

HG400A14

15

Thermal Overload

HG400A15

16

Centrifugal Plate

HG400A16

17

Upper Bearing

HG400A17

18

Motor Casing Pkg

HG400A18

19

Inside Cover

HG400A19

20

Head Cover Pkg.

HG400A20

21

Capacitor

HG400A21

22

Cable Gland

HG400A22

23

Gland Packing

HG400A23

24

Power  Cable

HG400A24

25

Handle

HG400A25

26

Outlet Discharge.

HG400A26

  No.

Description

Part No.

PARTS LIST  & DIAGRAM

SPECIFICATIONS

Model No.

Outlet Dia. (in/mm)

    1¼/32

    2/50

   2/50

Motor Output (Watts)

  150

   400

 400

Head Max. (M)

  7

   12

    8

Capacity Max. (L/min)

 120

    240

 240

Head Continuous (M)

  4

   8

  5.5

Capacity at Cont. Head (L/min)

   80

  130

 100

Dimensions LxWxH (mm)

  180x130x310

  240x180x430

 230x170x420

Weight (kg)

  7

   15

 18

Cable (Mxmm

2

)

  10x1.00

10x1.00

10x1.00

    

HSE 120

   HSE 120A
   HSE 200A

HSE 240

HSE 240A
HSE 250A

HSEC 400A