![Clarke HFBC12 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/clarke/hfbc12/hfbc12_operation-and-maintenance-instructions-manual_2614498003.webp)
3
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
THE CHARGING PROCESS
The HFBC12 has a sophisticated computer system that performs a 7 stage
automatic
charging cycle
.
The stages of this charging cycle are as follows
:
STAGE 1 DIAGNOSIS (UPON CONNECTION TO THE BATTERY)
• Polarity check: to make sure that the connections
are correct.
• Battery check: to make sure that the battery can accept a charge and
is not faulty, if it is the charger will not attempt to charge the battery.
Warning LEDs will come on if either test fails.
STAGE 2 PRE-CHARGE
STAGE 3 SOFT START
STAGE 4 CONSTANT CURRENT
Charges a discharged battery at a constant current depending on charge
mode selection
.
Charges until the battery is 80-90% re-charged
.
STAGE 5 CV(CONSTANT VOLTAGE)
This is a charging cycle for batteries nearly full. It will top off the battery to a full
charge.
STAGE 6 RESTING
Cuts off automatically when a full charge is reached.
STAGE 7 RESTORING
Automatic On-off Monitoring. The charger
will maintain and optimise the
battery indefinitely so long as it
remains connected to the battery
.
If the
battery falls below 12.8V DC, the charger will restart at stage one.