background image

20

EXPLODED DIAGRAM & PARTS LIST

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

NO DESCRIPTION

PART NO:

1

Left 
Crankcase

RKG72001

2

Right 
Crankcase

RKG72002

3

Bearing 6004

RKG72003

4

Hole Circlip

RKG72004

5

Oil Seal

RKG72005

6

Pin

RKG72006

7

Stub Am

RKG72007

8

Dentiform 
Flange Nut

RKG72008

9

Flange Bolt

RKG72009

10

Stub Am

RKG72010

11

Oil Seal 

RKG72011

12

Governor 
Shaft

RKG72012

13

Washer RKG72013

14

Governor Fork

RKG72014

15

Cross Head 
Bolt 

RKG72015

16

Spring Washer

RKG72016

17

Governor Arm RKG72017

18

Collar Bush

RKG72018

19

Weight Comp  RKG72019

20

Flange Bolt 

RKG72020

21

Crankshaft 
Assembly

RKG72021

22

Circlip

RKG72022

23

Piston Pin

RKG72023

24

Roller Bearing  RKG72024

25

Piston

RKG72025

26

Second Piston 
Ring

RKG72026

27

First Piston 
Ring

RKG72027

28

Cylinder 
Gasket

RKG72028

29

Cylinder

RKG72029

30

Cylinder Cap 
Gasket

RKG72030

31

Cylinder Cap

RKG72031

32

Flange Bolt

RKG72032

33

Thick Nut

RKG72033

34

The Cover Of 
Cylinder Cap

RKG72034

35

Flange Bolt

RKG72035

36

Ignition Coil 
Assembly

RKG72036

37

Clamp

RKG72037

38

Spring Washer  RKG72038

39

Cross Head 
Bolt

RKG72039

40

Flywheel

RKG72040

41

Flange Nut

RKG72041

42

Recoil Starter 
Assembly

RKG72042

43

Intake Valve 
Gasket

RKG72043

44

Intake Valve 
Assembly

RKG72044

45

Flange Bolt

RKG72045

46

Stub Am

RKG72046

47

Intake Gasket

RKG72047

48

Carburetor

RKG72048

49

Carburetor 
Gasket B

RKG72049

50

Carburetor 
Gasket A

RKG72050

51

Supporting 
Plate

RKG72051

52

Compression 
Spring

RKG72052

53

Cross Head 
Bolt

RKG72053

54

Rod Link

RKG72054

55

Tension Spring

RKG72055

56

Governor 
Spring

RKG72056

57

Control Panel

RKG72057

58

Capacitor

RKG72058

59

Self-tapping 
Screw

RKG72059

60

Alternator 
Stator

RKG72060

61

Alternator 
Rotor

RKG72061

NO DESCRIPTION

PART NO:

62

Flange Bolt

RKG72062

63

Rear Cover

RKG72063

64

Flange Bolt 

RKG72064

65

Dentiform 
Washer

RKG72065

66

Flange Bolt 

RKG72066

67

Muffler

RKG72067

68

Muffler Gasket RKG72068

69

Flange Bolt 

RKG72069

70

Cdi Winding

RKG72070

71

Spark Plug

RKG72071

72

Absorber

RKG72072

73

Fuel Tank 
(Blue)

RKG72073

74

Strainer

RKG72074

75

Fuel Tank Cap RKG72075

76

Handle

RKG72076

77

Cross Round 
Head Bolt

RKG72077

78

Washer

RKG72078

79

Fuel Switch

RKG72079

80

Fuel Cup

RKG72080

81

Dc Socket

RKG72081

82

Cross Head 
Bolt

RKG72082

83

Washer RKG72083

84

Nut

RKG72084

NO DESCRIPTION

PART NO:

Содержание G720

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS1011 720W PORTABLE GENERATOR MODEL NO G720 PART NO 8857800 ...

Страница 2: ...iod of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does...

Страница 3: ...r generators 5 SAFETY SYMBOLS 6 GENERATOR OVERVIEW 7 UNPACKING AND ASSEMBLY 8 BEFORE USING THE GENERATOR 8 Earth Connector 8 Adding the fuel oil mixture 9 USING YOUR GENERATOR 10 Starting the engine 10 Shutting down the generator 11 Voltmeter 12 MAINTENANCE 14 the spark plugs every 50 hours of use 14 the air filter every 150 hours of use 15 the fuel filter every 150 hours of use 16 TROUBLESHOOTING...

Страница 4: ...least 1 m 3 ft from walls or other equipment or the engine may overheat 2 Always ensure the generator is on a solid flat surface 3 Always ensure the surrounding area is free from any material that could burn or be damaged by heat 4 Never move or tilt the generator whilst it is switched on FIRE PREVENTION 1 Always switch the engine OFF when refuelling 2 Always refuel in a well ventilated area 3 Nev...

Страница 5: ...er use water or any other liquids to clean the generator 4 Make sure you ground earth the generator ADDITIONAL SAFETY RULES FOR GENERATORS 1 Always ensure the applied load does not exceed the generator rating Overloading the generator is dangerous and could cause serious damage 2 Always disconnect the generator when carrying out any maintenance 3 Always ensure the generator reaches operating speed...

Страница 6: ...nal com or Service clarkeinternational com SAFETY SYMBOLS Caution The user should be aware of a general hazard Dangerous Voltage Flammable Hot Surface Do not touch Poisonous fumes Do not use the generator in an enclosed space Read Instruction manual before use ...

Страница 7: ...international com GENERATOR OVERVIEW NO DESCRIPTION NO DESCRIPTION 1 Fuel cap 8 AC circuit breaker reset button 2 Carry handle 9 AC socket 3 Engine switch 10 DC socket reset button 4 Fuel valve 11 Spark plug cover 5 Starting handle 12 Spark plug 6 Choke 13 Voltmeter 7 Maintenance panel ...

Страница 8: ... or oil spillage The generator is correctly positioned for use See page 4 The fuel system and connectors are intact and there is no leakage NOTE Always use a funnel to fill the fuel tank so as to avoid accidental spillage of fuel If fuel is spilled it must be cleaned up before attempting to start the engine EARTH CONNECTOR Always connect the generator to an earth point The earth terminal is shown ...

Страница 9: ...asure the required amount of oil Add 0 02L of oil to every litre of fuel IMPORTANT Only use approved two stroke engine oil standard engine oil is not suitable Replace the lid on the container hold ing the petrol oil mixture and shake the container to mix the contents 4 Slowly pour the mixture into the fuel tank maximum 4 2L Do not overfill the fuel tank 5 Replace the fuel cap securely WARNING FUEL...

Страница 10: ...kets 2 Turn fuel valve to the ON position 3 Set the choke lever to the I position all the way to the left 4 Set the engine switch to the I ON position 5 Hold the generator handle firmly and pull the starting handle lightly until you start to feel resistance and then pull up sharply to start the engine NOTE You may have to do this more than once WARNING ONCE THE GENERATOR HAS STARTED RELEASE THE ST...

Страница 11: ... warmed up return the choke lever to the run position all the way to the right SHUTTING DOWN THE GENERATOR To stop the generator in an emergency simply set the engine switch to 0 OFF position 1 Turn off and disconnect any electric devices 2 Set the engine switch to the 0 OFF position 3 Turn the fuel valve to the OFF position ...

Страница 12: ...tage may drop if you place a heavy or highly resistive load on the generator CAUTION MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER IF IT BEGINS TO ACT ABNORMALLY OR STOPS SUDDENLY DISCONNECT IT FROM THE GENERATOR CAUTION MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM RATED LOAD FOR THE GENERATOR CAUTION ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E G DEVICES THAT CONTA...

Страница 13: ...sitive terminal and the black wire to the negative terminal of the battery 3 Connect the battery charging leads to the DC Socket The battery will begin to charge 4 Monitor the voltage across the battery regularly during charging and disconnect the battery when the voltage reaches 14 4 volts DC OVER LOAD PROTECTOR If the DC overload protector activates 1 Disconnect the battery charging leads and wa...

Страница 14: ...plug 3 Check for discoloration and use a wire brush to remove any carbon build up 4 Check the spark plug gap a with a feeler gauge it should be between 0 6 and 0 7 mm Adjust if necessary 5 Check the overall condition of the spark plug and replace if damaged NOTE Spark plugs are available from Clarke Spare Parts department 020 8988 7400 6 Reinstall the spark plug and replace the spark plug cap CAUT...

Страница 15: ...h it in a solution of warm water and mild detergent 5 Rinse thoroughly and leave it to dry once it is completely dry immerse the filter in clean engine oil and sqeeze the filter to remove excess oil If the air filter is damaged contact Clarke spare parts department for a replacement 6 Replace the filter into its original position and replace and secure the maintenance panel WARNING DO NOT USE FLAM...

Страница 16: ...Just inside the fuel tank is a fuel filter check this filter periodically and remove any contaminants which may have accumulated 1 Remove the fuel cap from the generator 2 Lift out the fuel filter 3 Clean the filter with solvent If the filter is damaged contact Clarke spare parts department for a replacement 4 Replace the filter and fuel cap ...

Страница 17: ...et the engine switch to on No fuel Add more fuel see page 9 Spark plug not working correctly Change the spark plug see page 14 The generator fails to generate electricity The device you are trying to power is faulty Make sure the device you want to power is working properly AC supply only The AC Circuit Breaker has activated Remove the appliance immediately wait for a 2 3 minutes and press the AC ...

Страница 18: ...nt cm3 63 Ignition type Recoil Fuel tank capacity L 4 2 Maximum run time h 6 5 hours 75 Load Guaranteed sound power level LWA dB 91 Sound pressure level LpA dB 69 5 Generator Rated Frequency Hz 50 Rated AC Voltage V 230 Rated Power W 650 Max Power W 720 Rated DC Voltage V 12 Rated DC Current A 5 3 Dimensions Length mm 380 Width mm 312 Height mm 319 Weight kg 17 ...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM PARTS LIST ...

Страница 20: ...37 Clamp RKG72037 38 Spring Washer RKG72038 39 Cross Head Bolt RKG72039 40 Flywheel RKG72040 41 Flange Nut RKG72041 42 Recoil Starter Assembly RKG72042 43 Intake Valve Gasket RKG72043 44 Intake Valve Assembly RKG72044 45 Flange Bolt RKG72045 46 Stub Am RKG72046 47 Intake Gasket RKG72047 48 Carburetor RKG72048 49 Carburetor Gasket B RKG72049 50 Carburetor Gasket A RKG72050 51 Supporting Plate RKG72...

Страница 21: ...21 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 22: ...22 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 23: ...power for computers etc Eco throttle for more greater fuel efficiency 12V Battery charging facility Low oil alert and overload shutdown IG2200 2200W Maximum output Inverter technology for clean stable power for computers etc Eco throttle for more greater fuel efficiency 12V Battery charging facility Low oil alert and overload shutdown For futher information on these or any of our products contact ...

Страница 24: ......

Отзывы: