![Clarke DEVIL 1600 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/clarke/devil-1600/devil-1600_user-instructions_2614851013.webp)
13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
SPECIFICATIONS
Please note that the details and specifications contained herein are correct
at the time of going to print. However CLARKE International reserve the right to
change specifications at any time without prior notice. Always consult the
heater’s data plate.
PROBLEM
CAUSE
REMEDY
Burner starts but stops
as the gas valve
button is released.
Thermocouple is not warm
enough or is faulty.
Repeat the starting
operation, keeping the
gas valve button
depressed for longer.
Weak gas supply.
Increase flame intensity
control valve setting.
Model Number
700
900/910SS
1600/1610ss
2100
Dimensions
(LxWxH) mm
425x215x340
500x215x370
500x215x370
640x220x385
Weight
5.3 kg
6.4 kg
6.4 kg
8.0 kg
Fuse Rating
13A
13A
13A
13A
Operating Volt-
age
230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
Rated Input
Power
90 W
110W
110W
135 W
Rated Input
0.7 A
0.7 A
0.7 A
0.7 A
Gas Consump-
tion (kg/hr)
0.63 -1.05
1.16-1.79
1.59-2.63
3.0-3.86
Air Flow (m3/hr)
500
535
580
690
Gas Pressure
(max)
300mBar
300mBar
300mBar
300mBar
Min Heat Out-
put (kWbtu)
8.8/30,000
17.6/60,000
22/75,000
35.2/120,000
Max Heat Out-
put (kW/btu
14.6-50,000
24.9/85000
36.6/125,000
49.8/170,000
Содержание DEVIL 1600