GC0816

GAS HEATERS

MODEL NOS: DEVIL 700, 900/910SS,1600/

1610SS & 2100 

PART NOS: 6920182, 6920186, 6920188, 6920190, 6920192, &6920194

Содержание DEVIL 1600

Страница 1: ...USER INSTRUCTIONS GC0816 GAS HEATERS MODEL NOS DEVIL 700 900 910SS 1600 1610SS 2100 PART NOS 6920182 6920186 6920188 6920190 6920192 6920194...

Страница 2: ...ed for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your st...

Страница 3: ...er use the heater where flammable vapours or if a high dust content is present in the air Only use with the voltage specified and ensure the heater is properly earthed Use only in well ventilated area...

Страница 4: ...long periods at maximum capacity be aware that it is possible for ice to form on the gas cylinder due to excessive evaporation Never direct hot air towards the cylinder in order to de ice Never use in...

Страница 5: ...ard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connecte...

Страница 6: ...nd reliable operation As with all mechanical equipment optimum performance will only be achieved if the correct operation and servicing procedures are followed GAS CONNECTION Connect the free end of t...

Страница 7: ...ttle and unscrew the regulator left hand thread 3 Ensure the replacement bottle screw threads and gas orifice is perfectly clean before screwing in the regulator valve tightly 4 Check to ensure there...

Страница 8: ...ignition system 4 The safety control system AIR SYSTEM An axial fan which is energised when switching on provides the air flow through the combustion chamber to provide a stream of hot air from the he...

Страница 9: ...ff the gas supply Additionally the machine is equipped with thermal overload protection which will intervene should the unit overheat shutting off the electrical supply STARTING PROCEDURE 1 Ensure the...

Страница 10: ...e fan is operating and that the air inlet and outlet are completely clear Also ensure that the electrode gap is correct and that the electrode is clean see Maintenance IMPORTANT Should the thermal ove...

Страница 11: ...components is gained by removing the access panel under the base of the heater which is secured by screws around the edge MONTHLY WHEN IN CONSTANT USE Check the spark plug for cleanliness and correct...

Страница 12: ...not ignite Connection installation incorrect Check that installation instructions are followed No spark at spark plug due to loose HT lead or PCB fault Check spark plug wire Tighten or re attach if l...

Страница 13: ...operation keeping the gas valve button depressed for longer Weak gas supply Increase flame intensity control valve setting Model Number 700 900 910SS 1600 1610ss 2100 Dimensions LxWxH mm 425x215x340 5...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM DEVIL 700 900 910SS...

Страница 15: ...ing 6 Orifice Assembly 24 Securing Nut 7 Flame Holder Assembly 25 Gas Valve 8 Orifice Nut 26 Male Fitting Connector 9 High Limit Switch Bracket 27 Solenoid Valve Assembly 10 High Limit Switch 28 Solen...

Страница 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM DEVIL 1600...

Страница 17: ...ing 6 Orifice Assembly 24 Securing Nut 7 Flame Holder Assembly 25 Gas Valve 8 High Limit Switch Bracket 26 Male Connector Fitting 9 Orifice Nut 27 Solenoid Valve Assembly 10 High Limit Switch 28 Solen...

Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM DEVIL 1610SS...

Страница 19: ...ting 6 Orifice Assembly 24 Securing Nut 7 Flame Holder Assembly 25 Gas Valve 8 High Limit Switch Bracket 26 Male Fitting Connector 9 Orifice Nut 27 Solenoid Valve Assembly 10 High Limit Switch 28 Sole...

Страница 20: ...20 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM DEVIL 2100...

Страница 21: ...ylinder 25 Extension Fitting 7 Front Guard 26 Securing Nut 8 Orifice Assembly 27 Gas Valve Button 9 Spark Plug Nut 28 Male Fitting Connector 10 Flame Holder Assembly 29 Solenoid Valve Assembly 11 Spar...

Страница 22: ...22 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING DIAGRAMS...

Страница 23: ...23 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 24: ......

Отзывы: