BATTERY ANALYSIS
METER READING
LOAD TEST
BATTERY CONDITION
OK (Green)
Battery capacity is OK. Battery may or may not be
fully charged. Check specific gravity of battery to
determine state of charge. If specific gravity is less
than full charge, check for electrical drain or possible
charging system trouble. Recharge battery to full
level.
Weak or Bad, But
Needle is Steady
(Yellow or Red)
Battery capacity is not satisfactory. Battery may be
either defective or not fully charged. Check specific
gravity to determine which condition exists. If
charging does not bring specific gravity to full charge
level, battery should be replaced.
Weak or Bad, But
Needle is Falling
(Yellow or Red)
Battery may be defective or very run down. Release
load switch and note voltmeter reaction. Voltage
recovery to 12 volt or above within seconds indicates
defective battery. Slow voltage recovery indicates
run down condition. For best results, check specific
gravity.
Charging System
(White)
If the display meter needle reads OK charging system
Is functional. If it falls on the low red or high red areas,
charging system may be malfunctioning.
TEMPERATURE COMPENSATION
Battery temperature
+20
°
F (-7
°
C)
0
°
F (-18
°
C)
-20
°
F (-29
°
C)
Decrease battery rating
by:
1 STEP
2 STEPS
3 STEPS
1 STEP
=
50 Cranking Amps
CAUTION: TO PREVENT OVERHEATING, ALLOW TESTER TO COOL FOR 5
MINUTES BEFORE DEPRESSING THE LOAD SWITCH AGAIN IF FURTHER
TESTING IS REQUIRED.