BATTERY ANALYSIS

METER READING

LOAD TEST

BATTERY CONDITION

OK (Green)

Battery capacity is OK. Battery may or may not be 
fully charged. Check specific gravity of battery to  
determine state of charge. If specific gravity is less 
than full charge, check for electrical drain or possible 
charging system trouble. Recharge battery to full 
level.

Weak or Bad, But  
Needle is Steady 
(Yellow or Red)

Battery capacity is not satisfactory. Battery may be 
either defective or not fully charged. Check specific 
gravity to determine which condition exists. If 
charging does not bring specific gravity to full charge 
level, battery should be replaced.

Weak or Bad, But  
Needle is  Falling 
(Yellow or Red)

Battery may be defective or very run down. Release 
load switch and note voltmeter reaction. Voltage 
recovery to 12 volt or above within seconds indicates  
defective battery. Slow voltage recovery indicates 
run down condition. For best results, check specific 
gravity.

Charging System 
(White)

If the display meter needle reads OK charging system 
Is functional. If it falls on the low red or high  red areas, 
charging system may be malfunctioning.

TEMPERATURE COMPENSATION

Battery temperature

+20

°

F (-7

°

C)

0

°

F (-18

°

C)

-20

°

F (-29

°

C)

Decrease battery rating 
by:

1 STEP

2 STEPS

3 STEPS

1 STEP 

50 Cranking Amps

CAUTION: TO PREVENT OVERHEATING, ALLOW TESTER TO COOL FOR 5 
MINUTES BEFORE DEPRESSING THE LOAD SWITCH AGAIN IF FURTHER 
TESTING IS REQUIRED.

Содержание CVT2

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0414 BATTERY TESTER MODEL NO CVT2 PART NO 6260103 ...

Страница 2: ...hase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Through purchase of this product the custo...

Страница 3: ...ertheless cause the readings to be inaccurate OPERATION With the meter disconnected from the battery ensure the gauge needle is set to zero using the screw on the front of the gauge as necessary BATTERY TEST Make sure that the battery contacts are clean and firm and that on small batteries there is absolutely no possibility of the clamps touching each other 1 Connect the RED clamp to the POSITIVE ...

Страница 4: ...does not bring specific gravity to full charge level battery should be replaced Weak or Bad But Needle is Falling Yellow or Red Battery may be defective or very run down Release load switch and note voltmeter reaction Voltage recovery to 12 volt or above within seconds indicates defective battery Slow voltage recovery indicates run down condition For best results check specific gravity Charging Sy...

Страница 5: ...mps are liable to come into contact with battery electrolyte it is advisable to wipe them clean and dry after use and apply a thin film of silicon grease to prevent the possibility of corrosion ITEM DESCRIPTION 1 Crocodile Clip 2 Sleeve Black handle Negative 3 Sleeve Red handle Positive 4 Gauge Assy 5 Gauge Cover 6 LOAD On Switch 7 Plastic Grommet ...

Страница 6: ...7400 E mail Parts clarkeinternational com or Service clarkeinternational com SPECIFICATION Model Number CVT2 Cable length including Clamps 460 mm Product Dimensions L x W x H 280 x 160 x 75 mm Weight 1 1 kg Part Number 6260103 ...

Страница 7: ...7 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 8: ......

Отзывы: