SAFETY WARNINGS

ELECTRIC SHOCK

1. Remove the plug from the socket and wait 5 minutes to allow the 

capacitors to discharge before carrying out any servicing or maintenance 
on this welder.

2. Do not touch live electrical parts.

3. Never use electrode holders or cables which are damaged.

4. Keep the working environment, equipment, cables and clothing free from 

grease, oil, moisture and dirt.

5. Ensure the welding machine has been correctly earthed.

6. The operator must be insulated from the floor and work bench using a dry 

insulation mat.

7. Always ensure a second person is present in case of accident.

8. Keep welding cables away from power cables.

9. Regularly inspect the condition of the cables for signs of damage.

10. Remove the plug from the mains socket when not in use.

11. Ensure the earth connector is secured to bare metal adjacent to the weld, 

and when not in use insulated for safety. - Keep all equipment well 
maintained.

12. The operator must prevent any gas cylinders in the vicinity of the work 

piece from becoming part of the welding circuit.

FUMES & GASES

1. The welding process generates hazardous fumes as a by-product. 

Inhalation of these fumes is hazardous to health.

2. Keep your head away from the weld to avoid breathing the fumes.

3. If welding in confined spaces ensure adequate ventilation and use a fume 

extractor.

By-products of welding can react to create a toxic/explosive environment

WARNING: WHEN USING ELECTRICAL TOOLS, BASIC SAFETY 
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF 
FIRE, ELECTRIC SHOCK AND PERSONAL INJURY 

WARNING: READ ALL THESE INSTRUCTIONS BEFORE ATTEMPTING TO 
OPERATE THIS PRODUCT AND KEEP THESE INSTRUCTIONS IN A SAFE PLACE.

Содержание CSW13T

Страница 1: ...OPERATING MAINTENANCE GC0418 rev 4 INSTRUCTIONS SPOT WELDERS MODEL NO CSW6T CSW13T PART NO 6030005 6030010...

Страница 2: ...invalid if the product is found to have been abused or tampered with in any way or not used for its intended purpose Faulty goods should be returned to their place of purchase no product can be return...

Страница 3: ...cables for signs of damage 10 Remove the plug from the mains socket when not in use 11 Ensure the earth connector is secured to bare metal adjacent to the weld and when not in use insulated for safety...

Страница 4: ...arrying any fuels with you e g cigarette lighters or matches PERSONAL PROTECTION 1 The body should be protected by suitable clothing 2 The use of neck protection may be necessary against reflected rad...

Страница 5: ...lace cover glass when broken pitted or spattered NOTE All protective wear inc masks head shields MUST comply with Personal Protective Equipment Directive 89 686 EEC ADDITIONAL SAFETY PRECAUTIONS FOR S...

Страница 6: ...ard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connecte...

Страница 7: ...et according to the thickness of metal to be welded 2 Changing selection for welding thickness 3 Changing resistance welding machine operating mode normal or pulse Selecting PULSE mode improves weldin...

Страница 8: ...national com PARTS IDENTIFICATION No Description No Description 1 Pressure Adjusting Screw 7 Data Label 2 Handle 8 Micro switch 3 Control Panel 13T 9 Weld Time Adjuster 6T 4 Electrode Arm 10 Operating...

Страница 9: ...r or not the longer electrode is located in the upper or lower arm depends upon the work in hand It may be necessary for example to reach over a lip in a workpiece necessitating the longer electrode t...

Страница 10: ...between the electrodes then tighten the electrode clamp The correct gap is now set 6 Remove the M6 screw and release the lever 7 Adjust the pressure to be exerted by the electrodes by turning the adju...

Страница 11: ...e mains supply Bring the lower electrode up to the work so that it is positioned directly beneath the point to be welded Depress the operating lever fully so that the microswitch is activated and hold...

Страница 12: ...used how clean or dirty the welding site is aggressive atmospheres etc Before use always inspect the welder checking for security and cleanliness of arms and electrodes to ensure they are in perfect...

Страница 13: ...tional com 3 Check all wiring for insulation damage or loose or oxidised connections Repair replace where necessary Check all screws and connections are tight and there are no signs of oxidation or ov...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com SCHEMATIC WIRING DIAGRAMS...

Страница 15: ...e page 17 2 Potentiometer Knob TT112299 11 Electrode see page 17 3 Timer PCB TT114236 12 Electrode see page 17 4 Microswitch TT122393 13 Cable Kit bush ringnut TT990046 5 Mains Cable TT132104 14 Upper...

Страница 16: ...PTION PART NO 1 Screw TT113908 10 Cable Kit bush ringnut TT990046 2 Control PCB TT114070 11 Pivot TT482887 3 Power PCB TT114085 12 Operating Lever TT322512 4 Microswitch TT122393 13 Adjuster Screw TT2...

Страница 17: ...accessories are available from your Clarke dealer Description Throat Part No Electrodes L 120mm 6030105 Electrodes L 250mm 6030107 Electrodes L 500mm 6030109 External Profile Electrodes 6030111 Intern...

Страница 18: ...ternational reserve the right to change specifications at any time without prior notice MODEL CSW6T CSW13T Part No 60300005 60300010 Weight 10 5 kg 11 kg Dimensions L x W x H mm 440 x 110 x 185 Power...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 20: ......

Отзывы: