5. A typical air line layout is shown above. If an automatic in-line filter/

regulator is used it will keep the tool in good condition. The lubricator 
should be adjusted to approx 2 drops per minute and SAE 10 oil should be 
used.

6. Never exceed the maximum operating pressure for the air tool. Ensure that 

air pressure does not exceed that stated in the specification for the tool 
when running. Higher pressures and contaminated air will shorten the life of 
the air tool due to faster wear and is a possible safety hazard.

INSTALLATION

1. Ensure the compressor is turned off. Before using the airline, drain water 

from the air reservoir at the compressor.

• The filter should be installed with reasonable accessibility for service 

whenever possible.

2. The filter should be installed upstream of regulator(s), lubricator(s), and 

cycling valve(s) in the air line, and should be as close as possible to the air 
tool(s) when used as a main line filter and/or as a final filter.

3. Keep pipe or tubing lengths to a minimum with the inside clean and free of 

dirt. Pipe joint compound should be used sparingly and applied only to the 
male pipe — never into the female port. 

4. Do not use PTFE tape to seal pipe joints — pieces have a tendency to 

break off and lodge inside the unit, possibly causing malfunction. 

5. Install the filter so that air flows as marked by the arrow on the filter body.

6. Installation should be downstream of the regulator but upstream of any 

lubricator.

Содержание CAT185

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0619 ISS 1 AIRLINE FILTER MODEL NO CAT185 PART NO 3120502...

Страница 2: ...uble free service If however having followed the instructions in this booklet carefully you encounter problems take the unit to your local CLARKE dealer SPECIFICATIONS GENERAL SAFETY RULES WORK ENVIRO...

Страница 3: ...l and sharp edges 7 Avoid damaging the component for example by applying excessive force of any kind 8 Always maintain the air tool with care Keep it clean for the best and safest performance COMPRESS...

Страница 4: ...fore using the airline drain water from the air reservoir at the compressor The filter should be installed with reasonable accessibility for service whenever possible 2 The filter should be installed...

Страница 5: ...iquids inside the bowl Take care to drain the liquids from the bowl whenever necessary and always keep the liquids below the baffle 3 The filter element should be replaced when the pressure drop acros...

Страница 6: ...ng or cloudiness ASSEMBLY 1 Lubricate the o rings the portion of the manual drain body that contacts the bowl and the hole in the manual drain body that accommodates the stem of drain valve with o rin...

Страница 7: ...y 3 Drain valve 4 O ring 5 Drain body 6 Bowl guard 7 Polycarbonate bowl 8 O ring 9 Metal bowl assembly 10 O ring 11 Drain valve 12 O ring 13 Drain body 14 Screw 15 Clamp 16 Lens 17 Seal 18 Metal bowl...

Страница 8: ......

Отзывы: