ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

If the plug has to be changed because it is not suitable for your socket, or 
because of damage, it must be removed and a replacement fitted, following 
the wiring instructions shown below. The old plug must be discarded safely, as 
insertion into a power socket could cause an electrical hazard

.

If the colours of the wires in the power cable do not agree with the markings 
on the plug.

• The BLUE wire must be 

connected to the 
terminal marked N or 
coloured black.

• The BROWN wire must 

be connected to the 
terminal marked L or 
coloured red.

• The YELLOW AND 

GREEN wire must be 
connected to the 
terminal marked E or 

 or coloured green.

AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING 
CURRENT OF LESS THAN 30 mA MUST BE USED.

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs. 

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS 
SUPPLY.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE 
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Содержание 7230696

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC1221 iss 5 ORIGINAL INSTRUCTIONS 750W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO PSV7A PART NO 7230696...

Страница 2: ...ay or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not ef...

Страница 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Страница 4: ...BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the term...

Страница 5: ...ow if required 1 Trim the adaptor to the required size Reducing the hose diameter will effect the maximum flow rate 2 Connect a suitable hose not supplied to the pump outlet Suitable hoses are availab...

Страница 6: ...ect the mains plug to the mains supply Always use a high sensitivity residual current device RCD which has a tripping current of less then 30mA 2 Switch the mains power supply on The pump will begin t...

Страница 7: ...e Repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 STORAGE When the pump is not being used for extended periods clean and dry it thoroughly a...

Страница 8: ...moving 7 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the outlet is not clogged or obstructed...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS LIST DIAGRAM...

Страница 10: ...Sheath 23 Adjustable Washer 7 Cable Gland 24 Impeller 7 1 Cable Gland 25 Nut 8 8uf Capacitor 26 Main Pump Housing 9 Cable Block 27 O ring 10 Self Tapping Screw 28 Pump Base 11 Rear Cover 29 Self Tappi...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATIONS OF CONFORMITY...

Страница 12: ......

Отзывы: