 POSITIONING AND CONNECTION

Remove all packaging and make sure that the unit contains no visible 
damage. Dispose of all packaging appropriately.

CONNECTING THE PUMP

1. Connect the outlet adaptor to the largest diameter hose available, as any 

restriction will reduce capacity and put unnecessary strain on the motor if 
a long run of discharge hose is being used.

•  The adaptor fitting allows for connection of 51 mm (2”) hoses which 

should be secured with a hose clamp.

• Suitable hoses are available from your local CLARKE dealer.

POSITIONING THE PUMP

1. It may be safer to raise and lower the pump into deep water using a rope 

attached to the lifting handle.

2. Place the pump in a vertical position resting on a firm, flat surface in the 

area that you want to drain. If there is sediment in the operating area, the 
pump should be placed vertically on house bricks, or similar but ensure 
they are not likely to collapse. Never

 

position the pump on sand, silt, mud 

or ground which is likely to collapse.

3. Keep the pump clear of sediment by standing it on a platform or brick or 

suspending from a rope attached to the handle if the pump is to be used 
where there may be silt or mud etc (e.g. garden ponds).

4. Route the hose as straight as possible. Excessive bending of the hose could 

obstruct the flow of water, reduce the pumping volume or clog the pump 
with mud, thus disabling the pumps function. If the hose is kinked at its base 
it will create air pockets in the pump, causing it to operate in a partially dry 
state. Take care to straighten any kinks or bends in the hose.

5. Do not operate the pump if the water is too shallow. This will be below the 

level of the outlet elbow with the impeller fully immersed.

6. Allowance must also be made for the overall width of the pump including 

the outlet elbow on one side.

• When the pump is being used in a permanent or semi-permanent 

installation, a non-return valve should be fitted in the delivery hose. 
Suitable hoses and valves are available from your CLARKE dealer.

• Take all necessary precautions as described on pages 4-5.

• The pump inlet must be fully submerged before being switched on.

Содержание 7230293

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS 1530W SEWAGE PUMP MODEL NO CSP1530 PART NO 7230293...

Страница 2: ...provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been cleared the therma...

Страница 3: ...rvice 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Water outlet 4 Lifting handle PUMP PERFORMA...

Страница 4: ...ge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it 5 NEVER direct the discharge flow t...

Страница 5: ...install the pump on sand silt or mud which is likely to shift or collapse 11 NEVER modify this pump in any way Use it only for the purpose for which it is designed SERVICING REPAIRS 1 ALWAYS have the...

Страница 6: ...his means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognized d...

Страница 7: ...in the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the ter...

Страница 8: ...e Never position the pump on sand silt mud or ground which is likely to collapse 3 Keep the pump clear of sediment by standing it on a platform or brick or suspending from a rope attached to the handl...

Страница 9: ...is not flowing 5 Disconnect the pump from the mains supply before placing it into or removing it from the water 6 NEVER carry the pump by the power cable Always use the handle or a rope tied securely...

Страница 10: ...salty water likely to leave chemical residues it should be flushed through with clean water before storage 4 When the pump is not being used for extended periods clean and dry it thoroughly and store...

Страница 11: ...onnect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inl...

Страница 12: ...T PARTS 1 Top cover 14 Shaft sleeve 2 Bearing cover 15 Key 3 Motor casing 16 Oil seal 4 Rotor 17 O ring 5 Stator 18 O ring 6 Bearing bracket 19 O ring 7 Seal cover 20 O ring 8 Impeller 21 Gasket 9 Pum...

Страница 13: ...roof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UK...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY EU...

Страница 16: ......

Отзывы: