Clarke 7230292 Скачать руководство пользователя страница 8

8

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

POSITIONING AND HOSE CONNECTION

Remove all packaging and make sure that the unit contains no visible 
damage. Dispose of all packaging appropriately.

CONNECTING THE PUMP

1. Connect the hose to the outlet adaptor.

2. ALWAYS use the largest diameter hose possible as any restriction will reduce 

capacity and put unnecessary strain on the motor especially if a long run 
of discharge hose is being used.

•  The outlet adaptor fitting allows for connection of 50 mm (2”) hose 

which should be secured with a hose clamp.

• Suitable hoses are available from your local CLARKE dealer.

POSITIONING THE PUMP

1. It may be safer to raise and lower the pump into deep water using a rope 

attached to the lifting handle.

2. Place the pump in a vertical position resting on a firm, flat surface in the 

area that you want to drain. If there is sediment in the operating area, the 
pump should be placed vertically on house bricks, or similar but ensure 
they are not likely to collapse. Never

 

position the pump on sand, silt, mud 

or ground which is likely to collapse.

3. Route the hose as straight as possible. Excessive bending of the hose could 

obstruct the flow of water, reduce the pumping volume or clog the pump 
with mud, thus disabling the pumps function. If the hose is kinked at its base 
it will create air pockets in the pump, causing it to operate in a partially dry 
state. Take care to straighten any kinks or bends in the hose.

4. DO NOT operate the pump if the water is too shallow. This will be below the 

level of the outlet elbow with the impeller fully immersed.

5. Allowance must also be made for the overall width of the pump including 

the outlet elbow on one side.

• When the pump is being used in a permanent or semi-permanent 

installation, a non-return valve should be fitted in the delivery hose. 
Suitable hoses and valves are available from your CLARKE dealer.

• Take all necessary precautions as described on pages 4-5.

• The pump inlet must be fully submerged before being switched on.

Содержание 7230292

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS DE WATERING PUMP MODEL NO CPCDP500 PART NO 7230292...

Страница 2: ...graph shown displays the characteristics graphically and describes the relation between the flow rate and the head for the pump Before attempting to use this product it is essential that you read this...

Страница 3: ...8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Water outlet elbow 4 Hose adaptor 5 Lifting handle Pu...

Страница 4: ...rge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it 5 NEVER direct the discharge flow...

Страница 5: ...ER install the pump on sand silt or mud which is likely to shift or collapse 11 NEVER modify this pump in any way Use it only for the purpose for which it is designed SERVICING REPAIRS 1 ALWAYS have t...

Страница 6: ...his means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised d...

Страница 7: ...the wires in the power cable do not agree with the markings on the plug The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal mar...

Страница 8: ...operating area the pump should be placed vertically on house bricks or similar but ensure they are not likely to collapse Never position the pump on sand silt mud or ground which is likely to collaps...

Страница 9: ...the power supply when the water has been pumped out Avoid running the pump continuously if the discharge hose has become obstructed and water is not flowing 5 Disconnect the pump from the mains suppl...

Страница 10: ...r 4 If the pump has been used for pumping swimming pool water or salty water likely to leave chemical residues it should be flushed through with clean water before storage 5 When the pump is not being...

Страница 11: ...5 The impeller may be jammed Disconnect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START...

Страница 12: ...13 Strainer base 2 Impeller 14 Stepped connector 3 Motor cover 15 Bearing bracket 4 Bearing cover 16 Motor housing 5 Power cable 17 Rotor assembly 6 Clamp flange 18 Stator assembly 7 Handle 19 Bearin...

Страница 13: ...ich will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UK...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY CE...

Страница 16: ......

Отзывы: