Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

4. ALWAYS use an approved cable extension suitable for the power rating of 

the pump (see specifications). The conductor size should also be at least 
the same size as that on the pump, or larger. When using a cable reel, 
always unwind the cable completely.

5. ALWAYS maintain the pump with care and keep it clean.

6. NEVER use for pumping flammable liquids or corrosive chemicals. These 

pumps are designed to pump water only.

7. NEVER abuse the electrical cable. Never use the cable for pulling or 

unplugging the pump. Damaged or tangled cables increase the risk of 
electric shock.

8. NEVER run the pump dry. Ensure the pump is immersed in water before 

starting. Switch the pump off immediately when the task is completed

9. NEVER pump water from a swimming pool when there is a person or animal 

still in the pool.

10. NEVER install the pump on sand, silt or mud which is likely to shift or 

collapse.

11. NEVER modify the pump in any way. Use it only for the purpose for which it 

is designed.

12. NEVER allow the pump to run dry or operate out of the water.

13. Submersible pumps should always be submerged and stored vertically.

14. Disconnect the pump from the mains supply before placing it into or 

removing it from the water.

15. NEVER insert your fingers into the pump whilst it is connected to the mains.

16. Keep the pump clear of any sediment by standing it on a platform or brick 

or suspending it at a suitable depth.

17. DO NOT use the pump if the water is liable to freeze, as this can cause 

damage to the pump. Remove the pump from the water and store it in a 
frost free location.

SERVICING & REPAIRS

1. ALWAYS have the pump serviced by your local CLARKE dealer, using only 

identical replacement parts. This will ensure the safety of the pump is 
maintained. The use of non standard parts could be hazardous.

2. NEVER attempt any repairs yourself unless suitable qualified. If you have a 

problem with the pump contact your local CLARKE dealer.

3. ALWAYS disconnect the pump from the electrical supply before placing it 

into, or removing from the water, and before any cleaning or 
maintenance.

Содержание 7230291

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS 870W GRINDER SLURRY PUMP MODEL NO CGP870 PART NO 7230291...

Страница 2: ...he pump The pump is provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been...

Страница 3: ...ce 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Outlet hose adaptor 4 Lifting handle Pump Perf...

Страница 4: ...the pump 3 NEVER direct the water discharge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to opera...

Страница 5: ...se 11 NEVER modify the pump in any way Use it only for the purpose for which it is designed 12 NEVER allow the pump to run dry or operate out of the water 13 Submersible pumps should always be submerg...

Страница 6: ...in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of w...

Страница 7: ...in the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the ter...

Страница 8: ...he pump on sand silt mud or ground which is likely to collapse 3 Keep the pump clear of sediment by standing it on a platform or brick or suspending from a rope attached to the handle if the pump is t...

Страница 9: ...and water is not flowing 5 DO NOT ALLOW THE PUMP TO RUN DRY 6 Disconnect the pump from the mains supply before placing it into or removing it from the water 7 NEVER insert your fingers into the pump w...

Страница 10: ...g swimming pool water or salty water likely to leave chemical residues it should be flushed through with clean water before storage 4 When the pump is not being used for extended periods clean and dry...

Страница 11: ...onnect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inl...

Страница 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Страница 13: ...ring 3 Bearing cover 19 O ring 4 Strainer base 20 Washer 5 Rotor and shaft 21 Gasket 6 Stator and coil 22 Gasket 7 Flat washer 23 Outlet connector 8 Pump housing 24 Handle ring 9 Impeller 25 Washer 1...

Страница 14: ...e of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATIONS OF CONFORMITY...

Страница 16: ......

Отзывы: