Clarke 7230291 Скачать руководство пользователя страница 4

4

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

SAFETY PRECAUTIONS

WORK AREA

1. Keep the work area clean and well lit. Floors should always be kept clear. 

Cluttered or dark areas invite accidents.

2. Keep children and bystanders away while operating the pump. 

Distractions can cause loss of control.

3. Remember, the operator or user is responsible for accidents or hazards 

occurring to other people or their property.

PERSONAL SAFETY

1. ALWAYS stay alert, watch what you are doing and use common sense 

when operating this pump. Do not install the pump while you are tired or 
under the influence of medication, drugs or alcohol. A moment of 
inattention can result in personal injury.

2. DO NOT over-reach. Keep your proper footing and balance at all times 

when positioning the pump.

3. NEVER direct the water discharge towards electrical wiring or equipment.

4. ALWAYS store the pump out of reach of children and do not allow persons 

unfamiliar with these instructions to operate it.

5. NEVER direct the discharge flow towards another person.

6. ALWAYS thoroughly familiarise yourself with this pump & its operation and 

follow all instructions in this manual.

7. ALWAYS ensure that the pump is properly positioned where necessary to 

prevent it from moving during operation, and that the immediate area 
surrounding the pump is kept clear.

GENERAL USE AND CARE OF THE PUMP

1. An approved Residual Current Device (RCD) must be used when pumping 

from ponds or swimming pools.

2. ALWAYS lift the pump using the handle and use a rope or chain attached if 

necessary to lower it into the water. NEVER lift or carry the pump by the 
power cable.

3. NEVER use this pump if any part is damaged. ALWAYS check the plug, 

mains cable for damage before use. Have any damage inspected and 
repaired by your local CLARKE dealer.

Содержание 7230291

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS 870W GRINDER SLURRY PUMP MODEL NO CGP870 PART NO 7230291...

Страница 2: ...he pump The pump is provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been...

Страница 3: ...ce 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Outlet hose adaptor 4 Lifting handle Pump Perf...

Страница 4: ...the pump 3 NEVER direct the water discharge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to opera...

Страница 5: ...se 11 NEVER modify the pump in any way Use it only for the purpose for which it is designed 12 NEVER allow the pump to run dry or operate out of the water 13 Submersible pumps should always be submerg...

Страница 6: ...in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of w...

Страница 7: ...in the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the ter...

Страница 8: ...he pump on sand silt mud or ground which is likely to collapse 3 Keep the pump clear of sediment by standing it on a platform or brick or suspending from a rope attached to the handle if the pump is t...

Страница 9: ...and water is not flowing 5 DO NOT ALLOW THE PUMP TO RUN DRY 6 Disconnect the pump from the mains supply before placing it into or removing it from the water 7 NEVER insert your fingers into the pump w...

Страница 10: ...g swimming pool water or salty water likely to leave chemical residues it should be flushed through with clean water before storage 4 When the pump is not being used for extended periods clean and dry...

Страница 11: ...onnect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inl...

Страница 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Страница 13: ...ring 3 Bearing cover 19 O ring 4 Strainer base 20 Washer 5 Rotor and shaft 21 Gasket 6 Stator and coil 22 Gasket 7 Flat washer 23 Outlet connector 8 Pump housing 24 Handle ring 9 Impeller 25 Washer 1...

Страница 14: ...e of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATIONS OF CONFORMITY...

Страница 16: ......

Отзывы: