Clarke 7120315 Скачать руководство пользователя страница 8

8

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

WARNING:-

DO NOT place any such obstruction on the suction side 

(inlet Port) of the pump unless it is an isolator valve in a gravity fed 
system. It is also IMPORTANT to note, that these pumps should not be 
operated with the delivery valve completely closed.

• If there is any chance of freezing, protect the pump and pipework 

with suitable lagging. The formation of ice may cause serious 
damage.

IMPORTANT: The pump MUST NOT be connected to the mains supply until all 
hose/pipe installation is completed. DO NOT RUN THE PUMP DRY

NOTE: 

If any part of the system is to be connected to the mains water 

supply ensure that local water authority regulations are observed.

Содержание 7120315

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1120 CPE WATER PUMP MODEL NO CPE30A1 PART NO 7120315...

Страница 2: ...ed it is installed and used in the correct way If the pump is left in an exposed position it should be protected from the elements especially frost Before attempting to use this product please read th...

Страница 3: ...Parts clarkeinternational com or Service clarkeinternational com PUMP SPECIFICATION Motor size 3 HP Water Classification Clean Maximum Delivery 800 L min Maximum Rated Head 18 m Supply 230V 50Hz Outl...

Страница 4: ...allow persons unfamiliar with these instructions to instal or operate the pump 6 ALWAYS ensure that the pump is properly installed to prevent it from moving during operation and that the immediate ar...

Страница 5: ...utlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in it s operating position Mount the pump on raised blocks or a purpose built platform to pro...

Страница 6: ...he BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the t...

Страница 7: ...ustrated in Fig 2 so as to retain water in the suction system and more importantly to prevent the possibility of large foreign objects entering the pump body FURTHER CONSIDERATIONS Strain caused by vi...

Страница 8: ...these pumps should not be operated with the delivery valve completely closed If there is any chance of freezing protect the pump and pipework with suitable lagging The formation of ice may cause serio...

Страница 9: ...cess and it is essential that a non return valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise...

Страница 10: ...lowing use both inside and out It should then be drained and covered over if not already sheltered from the weather If the pump is seized following a period of inactivity it may be possible to free it...

Страница 11: ...ause and clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for b...

Страница 12: ...oes not effect your statutory rights High friction losses in the suction line Avoid unnecessary curves restrictions or valves Pump badly sited result ing in suction lift too high Set pump as close as...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM CPE30A...

Страница 14: ...GM8016 8 Plug GM6230 25 Fan cover GM8017 9 Screw GM6235 26 Junction box cover GM8018 10 Screw GM6261 27 Junction box GM8025 11 Mechanical seal GM6334 28 Motor stator GM8052 12 Counterface GM6346 29 Mo...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: