Clarke 7120315 Скачать руководство пользователя страница 4

4

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

GENERAL SAFETY PRECAUTIONS

Before using this equipment it is in your own interest to read and pay attention 
to the following safety rules.

1.

NEVER 

use for pumping flammable liquids or corrosive chemicals. This 

pump is designed to pump clean water only.

2.

ALWAYS 

keep the working area clean and well lit. Floors should always be 

kept clear. Cluttered or dark areas invite accidents.

3.

NEVER 

over-reach. Keep your proper footing and balance at all times 

when installing or maintaining the pump.

4.

NEVER 

direct any water discharge towards electrical wiring or equipment.

5.

ALWAYS 

thoroughly familiarise yourself with this pump & its operation, and 

follow all instructions in this manual.

 

Never allow persons unfamiliar with 

these instructions to instal or operate the pump.

6.

ALWAYS 

ensure that the pump is properly installed to prevent it from moving 

during operation, and that the immediate area surrounding the pump is 
kept clear.

7.

ALWAYS

 maintain the pump with care and keep it clean for best / safest 

performance.

8.

NEVER 

use this product if any part is damaged. Have it inspected and 

repaired by your local Clarke dealer. Always turn the pump off before 
carrying out any maintenance.

9.

NEVER 

modify this pump in any way. Use it ONLY for the purpose for which it 

is designed.

10.

ALWAYS 

have the pump serviced by your local Clarke dealer, using only 

identical replacement parts. This will ensure the safety of the pump is 
maintained. The use of non standard parts could be hazardous.

11.

NEVER 

allow the pump to run dry.

WARNING: ALWAYS CONNECT THE PUMP TO AN EARTHED POWER SUPPLY 
VIA AN RCD.

CAUTION: THIS PUMP IS NOT A SUBMERSIBLE PUMP. ON NO ACCOUNT 
SHOULD IT EVER BE IMMERSED IN WATER.

Содержание 7120315

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1120 CPE WATER PUMP MODEL NO CPE30A1 PART NO 7120315...

Страница 2: ...ed it is installed and used in the correct way If the pump is left in an exposed position it should be protected from the elements especially frost Before attempting to use this product please read th...

Страница 3: ...Parts clarkeinternational com or Service clarkeinternational com PUMP SPECIFICATION Motor size 3 HP Water Classification Clean Maximum Delivery 800 L min Maximum Rated Head 18 m Supply 230V 50Hz Outl...

Страница 4: ...allow persons unfamiliar with these instructions to instal or operate the pump 6 ALWAYS ensure that the pump is properly installed to prevent it from moving during operation and that the immediate ar...

Страница 5: ...utlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in it s operating position Mount the pump on raised blocks or a purpose built platform to pro...

Страница 6: ...he BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the t...

Страница 7: ...ustrated in Fig 2 so as to retain water in the suction system and more importantly to prevent the possibility of large foreign objects entering the pump body FURTHER CONSIDERATIONS Strain caused by vi...

Страница 8: ...these pumps should not be operated with the delivery valve completely closed If there is any chance of freezing protect the pump and pipework with suitable lagging The formation of ice may cause serio...

Страница 9: ...cess and it is essential that a non return valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise...

Страница 10: ...lowing use both inside and out It should then be drained and covered over if not already sheltered from the weather If the pump is seized following a period of inactivity it may be possible to free it...

Страница 11: ...ause and clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for b...

Страница 12: ...oes not effect your statutory rights High friction losses in the suction line Avoid unnecessary curves restrictions or valves Pump badly sited result ing in suction lift too high Set pump as close as...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM CPE30A...

Страница 14: ...GM8016 8 Plug GM6230 25 Fan cover GM8017 9 Screw GM6235 26 Junction box cover GM8018 10 Screw GM6261 27 Junction box GM8025 11 Mechanical seal GM6334 28 Motor stator GM8052 12 Counterface GM6346 29 Mo...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: