TROUBLESHOOTING

Problem

Cause

Solution

Pump does not run.

Thermal protection has 
been activated.

If the motor has over-
heated, wait for it to cool 
down before trying 
again.

Faulty power connection Check and repair con-

nection as necessary.

No mains supply

Check fused power   
supply and replace fuse 
if necessary (check fuse 
rating). Check circuit 
breaker

Impeller seized/blocked

Disconnect pump from 
power supply.            
Investigate cause and 
clear blockage

Pump fails to prime

Air leaks through suction 
hose joints (damaged 
hose, broken clamp, 
damaged.

Repair connections/
replace hose as          
necessary.

Blocked inlet hose

Check pipeline for  
blockage. Check any 
inlet valve fitted is fully 
open.

Pump runs but gives poor 
output

Congested material 
inside pump

Clean out & backflush 
pump.

Suction or delivery line 
obstructed.

Remove obstruction and 
ensure there are no kinks 
in delivery line.

Inlet pipe leakage.

Check inlet pipe and 
connector for leaks. 
Tighten as required.

Air leaks through       
damaged seal.

Renew seal.

Impeller damaged and 
making poor seal.

Return to your Clarke 
dealer for repair

Impeller / mechanical 
seal is badly worn.

Return to your Clarke 
dealer for repair.

Содержание 7120310

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1120 CPE WATER PUMP MODEL NO CPE20A1 PART NO 7120310...

Страница 2: ...ed it is installed and used in the correct way If the pump is left in an exposed position it should be protected from the elements especially frost Before attempting to use this product please read th...

Страница 3: ...clarkeinternational com or Service clarkeinternational com PUMP SPECIFICATION Water Classification Clean Maximum Delivery 500 L min Rated Head 2 14 m Maximum Suction Lift 18 m Supply 230V 50Hz Motor H...

Страница 4: ...allow persons unfamiliar with these instructions to instal or operate the pump 6 ALWAYS ensure that the pump is properly installed to prevent it from moving during operation and that the immediate ar...

Страница 5: ...utlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in it s operating position Mount the pump on raised blocks or a purpose built platform to pro...

Страница 6: ...he BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the t...

Страница 7: ...ustrated in Fig 2 so as to retain water in the suction system and more importantly to prevent the possibility of large foreign objects entering the pump body FURTHER CONSIDERATIONS Strain caused by vi...

Страница 8: ...these pumps should not be operated with the delivery valve completely closed If there is any chance of freezing protect the pump and pipework with suitable lagging The formation of ice may cause serio...

Страница 9: ...cess and it is essential that a non return valve be fitted to the end of the suction pipe 4 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise...

Страница 10: ...lowing use both inside and out It should then be drained and covered over if not already sheltered from the weather If the pump is seized following a period of inactivity it may be possible to free it...

Страница 11: ...ause and clear blockage Pump fails to prime Air leaks through suction hose joints damaged hose broken clamp damaged Repair connections replace hose as necessary Blocked inlet hose Check pipeline for b...

Страница 12: ...oes not effect your statutory rights High friction losses in the suction line Avoid unnecessary curves restrictions or valves Pump badly sited result ing in suction lift too high Set pump as close as...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM CPE20A...

Страница 14: ...GM6999 8 Flexolite washer GM6186 26 Motor stator GM7168 9 Plug GM6209 27 N a N a 10 Plug GM6213 28 Junction box cover GM8018 11 Screw GM6235 29 Screw GM8084 12 Screw GM6236 30 Motor shaft GM8643 13 M...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: