background image

 SAFETY PRECAUTIONS

ALWAYS keep the unit in an upright position to avoid damage to the cooling
system, locate on a flat stable surface.

DO NOT place the unit close to curtains or other objects (min. distance 0.5M).

ALWAYS  ensure that the air inlets and outlets are NOT blocked or covered.

Operate this unit in an ambient temperature of between 5°C and 35°C.

When using the unit to dry clothes, keep clothing a safe distance from the
unit to prevent water from dropping in.

NEVER place anything on top of the unit and DO NOT cover with any kind of
material while in use.

This product is intended for domestic and small office use ONLY and NOT for
commercial, industrial or outside use.

To protect against electric shocks, DO NOT immerse unit, plug or cord in water
or spray with liquids.

DO NOT operate the unit if the cord or plug becomes damaged, return to
an authorised service facility for examination and repair.

ALWAYS switch the unit OFF before unplugging from the mains supply, failure
to do so could cause damage to the electronics in the unit.

ALWAYS empty the water tank before storing the unit away.

ALWAYS unplug the unit from the supply when not in use, when emptying the
water tank, and when moving to a new location.

NEVER pull the cord to disconnect the unit from the power supply, always
grip the power plug and pull from the socket.

Close supervision is necessary when any appliance is used by or near
children and pets.

DO NOT run the power cord under carpeting, or cover with rugs or runners.
Arrange the cord away from areas where it may be tripped over.

NEVER operate or store the unit in direct sunlight.

ALWAYS take the unit to a qualified service engineer for repair. Repairs
carried out by unqualified people may cause damage to the unit or injury
to persons or property and invalidate the warranty.

WARNING:

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING

This appliance is intended for domestic and small office use ONLY. Any
other use is not recommended by the manufacturer and may cause fire,
electric shocks or other injury to person or property.

Содержание 6470619

Страница 1: ...USER INSTRUCTIONS 0608 DEHUMIDIFIER MODEL NO CD1155 Part No 6470619 DEHUMIDIFIER ...

Страница 2: ...Copyright CLARKE International All rights Reserved 03 2006 Waste electrical products should not be disposed of with household waste Please dispose of at your local recycling facility Guarantee 1 Safety Precautions 2 Electrical Connections 3 Technical Specification 4 Parts Description 5 Setup Operation 6 Maintenance 10 Troubleshooting 11 Parts List 12 CLARKE GUARANTEE This CLARKE product is guarant...

Страница 3: ...F before unplugging from the mains supply failure to do so could cause damage to the electronics in the unit ALWAYS empty the water tank before storing the unit away ALWAYS unplug the unit from the supply when not in use when emptying the water tank and when moving to a new location NEVER pull the cord to disconnect the unit from the power supply always grip the power plug and pull from the socket...

Страница 4: ...ble There is a danger of electric shock if it is subsequently inserted into a socket outlet NEVER use the plug without the fuse cover fitted Should you wish to replace a detached fuse carrier ensure that the correct replacement is used as indicated by marker or colour code The fuse in the plug MUST be replaced with one of the same rating 13amps and this must be approved to BS1362 IMPORTANT If in a...

Страница 5: ...Domestic Small office Product Specification Operating Voltage 230V Motor Wattage 250W Operating Temperature 5 C 35 C Max Extraction Rate 10 Litres Day Tank Capacity 2 1 Litres Dimensions Weights Product length x width x height 290 x 325 x 452mm Weight 11 5Kg gross 10Kg nett ...

Страница 6: ...FRONT VIEW PARTS DESCRIPTION REAR VIEW Air inlet Control panel Handle Bucket Finger grip to pull out bucket both sides Filter Drain connector Air outlet Power cord storage ...

Страница 7: ...NNING Illuminates when the dehumidifier is ON 4 Humidity Control Turn the dial to OFF to stop the machine Turn the dial to CON for continuous dehumidification As a safety feature the unit will run for three minutes before the compressor starts OPERATION NOTE This unit operates within an ambient temperature of 5 C to 35 C 1 Ensure that the unit is connected to the power socket 2 Make sure the water...

Страница 8: ...r out carefully lift and pour the water away then replace back into the correct position CONTINUOUS WATER DRAIN For continuous water drainage use a hose with an inner diameter of 14 mm not supplied 1 Turn the drain cover anticlockwise to remove 2 Remove the tube stopper from the drainage tube 3 Attach the hose to the drainage tube 4 The hose should be lead to the drain with no sharp bends 5 Make s...

Страница 9: ...e filter is behind the front grille reach underneath and you will be able to pull the filter down until it is fully out 3 Clean the filter with a vacuum cleaner if it is very dirty you can wash them in warm water DO NOT use hot or soapy water NOTE Make sure the filter is completely dry before replacing it in the unit NOTE Do not bend the filter RELOCATING THE UNIT 1 ALWAYS turn OFF and unplug from...

Страница 10: ...air filter NOTE This model operates within a temperature range of 5 C to 35 C Do not operate the unit below 5 C This could cause an accumulation of ice on the unit If this occurs unplug the unit and move to a place where water can be drained away Whenever the compressor stops there will be at least a three minute wait before it will restart this ensures a smooth start and also helps to extends the...

Страница 11: ...hose supplied by CLARKE international or one of its recognised dealers may be hazardous and could invalidate the guarantee PARTS LIST ITEM DESCRIPTION PART NO 1 Air Filter EHCD115501 2 Control Panel EHCD115502 3 Bucket EHCD115503 4 Power Cord EHCD115504 NOTES ...

Страница 12: ......

Отзывы: