![Clarke 6470611 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/clarke/6470611/6470611_operation-and-maintenance-instructions-manual_2614602012.webp)
12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
• When started, the compressor will start 3 seconds later and when it is
shut down, the fan will run for 3 seconds.
• If a fault of the humidity sensor occurs, the machine will turn to the
continuous dehumidifying mode.
• If a fault of the coil sensor occurs, the machine will turn to the timing
defrosting mode (See Defrosting Mode).
PROTECTION FUNCTION
• Once shut down, the compressor will take 3 minutes to restart. Quick
start is available for the first power-on.
•
Power off memory:
For abrupt power outage or accidental unplugging,
the machine will automatically return to the operating state right before
the ‘incident’, and continue at that state for the next power-on.
DEFROSTING MODE
Defrosting
Mode
Description
Automatic
Defrosting
Sensor at Normal State 1: It enters this mode when the
compressor runs constantly for 30
minutes and the coil temperature is
tested to be < or = 1
o
C.
2: In defrosting, the compressor stops
running, the fan continues running
and the defrost light is on.
Timing
Defrosting
In this mode, the machine will defrost for 8 minutes and then
switch to standby mode.
Содержание 6470611