OPERATION & MAINTENANCE
INSTRUCTIONS
DL0422 Iss 1
50L INDUSTRIAL DEHUMIDIFIER
MODEL NO: IDH50L
PART NO: 6470611
Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS DL0422 Iss 1 50L INDUSTRIAL DEHUMIDIFIER MODEL NO IDH50L PART NO 6470611 ...
Страница 2: ...o their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Recycle unwanted materials instead of disposing of them as waste All unwanted accessories and packaging should be sorted and taken to a recycling centre for disposal in a manner which is compatible with the environment By purchasing...
Страница 3: ...ng instructions shown below The old plug must be disposed of safely as insertion we would emphasise the electrical hazard The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal marked E or or coloured green We strongly recommend that this machine...
Страница 4: ...RVIEW Contents List 1 x 50L Dehumidifier 2 x Wheels 1 x Wheel Axle Rod Inc Nuts Washers 4 x Axle Fixing Screws 1 x Drainage Pipe No Description 1 Handle 2 Control Panel 3 2 x Wheels 4 Continuous Drainage Pipe Outlet Hole 5 2 x Feet 6 5 Litre Internal Water Tank 7 Air Inlet and Filter 8 Air Filter Pull Tab ...
Страница 5: ...ble 8 DO NOT install the appliance in rooms containing gas oil or fuel 9 DO NOT install near sources of heat 10 DO NOT use the appliance on inclined surfaces 11 Keep the appliance away from inflammable substances alcohol etc or pressurised containers e g aerosol cans 12 DO NOT rest heavy or hot objects on top of the appliance 13 ALWAYS transport the appliance upright Wait at least 1 hour after tra...
Страница 6: ...of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters stoves or other sources of ignition Refrigerant gas may be odourless DO NOT use the product and contact the retailer for advice if damage has occurred to the unit which may have compromised the refrigerant system Any repairs or maintenance must ...
Страница 7: ...urrent Rated Load 4 0A 30o C RH 80 3 4A 27o C RH 60 Power 900W 30oC RH 80 750W 27oC RH 60 IP Rating IP22 Dehumidifying Extraction Rate 50 litres day 30oC RH 80 30 litres day 27oC RH 60 Max Suction Pressure 1 0Mpa Max Discharge Pressure 2 5Mpa Max Air Flow Rate 300m3 h Working Space 50 120m3 Water Tank 7 litre tank with 5 litre capacity Operating Temperature 5oC 35oC Refrigerant 200g of R290 Hydroc...
Страница 8: ... the handle in position using the fixing screws provided WHEELS 1 Incline the machine body as shown and fix the wheel axle on the bottom of the machine body using the 4 screws 2 Using the nuts and washers fix the wheels to the axle rod 3 Once the wheels have been installed place the machine in the upright position NOTE Once assembly is complete leave the machine to stand for a minimum of 1 hour th...
Страница 9: ...ing 6 Timer Set Button Operation Instructions On Off Button 5 Switches the machine On and Off Button 8 Adjusts different set values in different states 1 Increases the humidity value set RH 10 to 95 2 Increases the timing Hours set 00 to 24 Button 7 Adjusts different set values in different states 1 Decreases the humidity value set RH 10 to 95 2 Decreases the timing Hours set 00 to 24 Timer Button...
Страница 10: ...the tank is removed and will not turn off until the tank is empty and correctly seated back in the machine PREPARATION FOR CONTINUOUS DRAINING An external drainage pipe enables continuous dehumidifying without having to empty the water tank 1 Extract the water tank from the machine and remove the plug from the water tank spout 2 Locate the external drainage pipe and feed it through the drainage pi...
Страница 11: ...nd the Timing On icon will flicker Ranging from 0 to 24 hours and 0 hours as default SETTING OF TIMER POWER OFF 1 When the machine is powered on press the Timing button 2 The Timing Off icon will flicker and the time set will flicker on the display screen 3 Press the or buttons to adjust the timing The dehumidifier will make a sound once the button is pressed The time set will increase or decrease...
Страница 12: ...e 3 minutes to restart Quick start is available for the first power on Power off memory For abrupt power outage or accidental unplugging the machine will automatically return to the operating state right before the incident and continue at that state for the next power on DEFROSTING MODE Defrosting Mode Description Automatic Defrosting Sensor at Normal State 1 It enters this mode when the compress...
Страница 13: ...ter upwards and out using the tab 2 Wash the filter under running water to remove any dust and dirt 3 Allow the filter to dry naturally 4 Refitting is the reverse process NOTE The frequency depends on the duration and the level of dust in the environment If the machine is being used regularly it is recommended that you clean the filter every 2 weeks STORAGE Unplug from the mains socket Empty any w...
Страница 14: ...ature is too low Do not use the dehumidifier Room temperature too high humidity too low In dry conditions the dehumidification ability will reduce Air filter blocked Remove any dirt or obstruction from the air intake Noise is abnormal during operation Dehumidifier is positioned incorrectly Check that dehumidifier is placed on a flat level surface Air filter blocked Remove any dirt or obstruction f...
Страница 15: ...ational com DISPLAY CODES ELECTRICAL DIAGRAM Display Code Instruction Action E1 Fault with coil sensor See Defrosting Mode E2 E3 Fault with humidity and or temperature sensor Replace temperature and humidity sensor EE Refrigerant leakage Contact CLARKE service department if EE signal remains ...
Страница 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS DIAGRAM ...
Страница 17: ...l Panel Holder 42 Foot Bracket 10 Main Body Shell 43 Foot Pad 11 Motor Bracket 44 Wheel Axle 16mm x 462mm 12 220V 50Hz Fan Motor 45 Wheel 13 250mm Fan Blade 46 Foot Rest 14 Partition Plate 47 Compressor Capacitor 15 Condenser 48 Compressor Bolt M8 x 40 16 Evaporator 49 Compressor Mat 17 Bracing Rod 50 Compressor 18 Sensor Bracket 51 Power Cable 19 Temp Humidity Sensor 52 Power Cable Storage Clip 2...
Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UKCA ...
Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY CE ...