8
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
ASSEMBLY AND INSTALLATION
Ensure the planer is located where there is adequate light and a suitable
power supply. If cable a extension is used, ensure it does not trail along the
workshop floor as this could be extremely hazardous.
There must be sufficient room for the workpiece to move through its entire
length.
Similarly, there must be sufficient room so that the operator does not need to
stand in line with the wood during the planing process.
The planer may be used as a mobile
unit, but for greater stability we
recommend it is bolted to a strong,
firm workbench. The dimensions for
the mounting holes are shown:
Alternatively, mount the planer on a
strong piece of plywood of at least
15mm in thickness, with length
550mm and width 380mm minimum.
The plywood platform, with planer
mounted, is then clamped firmly to a
workbench when required.
ATTACHING THE ANGLE FENCE
The peg - ‘A’ locates in the slotted
hole - ‘B’. It may be necessary to
screw the peg down a little in order
for the peg to locate properly.
The Hex. socket head screw with
washers (in the bag of loose parts), is
used to secure the fence to the
table, through slot ‘C’, into threaded
hole ‘D’.
The fence may be set and locked at
any angle. Use a template or angle
gauge if accuracy is required.
Содержание 6462130