CIRCUIT BREAKER TRIPPING
Circuit breakers protect electrical circuits and motors from damage due to overload conditions. If a circuit breaker trips, turn the Master Key Switch
(A)
OFF and remove the key. Then try to determine the cause. Once the problem has been corrected, reset the circuit breaker by pushing the
button in. If the button does not stay in, wait 5 minutes and try again. If the circuit breaker trips repeatedly, call Clarke for service.
Possible cause for the Control Circuit Circuit Breaker
(23)
tripping may be:
1
Short circuit in the wiring - have your Clarke Service Technician service the machine
Possible causes for the Wheel Drive Circuit Breaker
(24)
tripping may be:
1
Debris wrapped around the drive wheel axle.
2
Worn out drive motor bearings.
3
Continuous use on ramps.
POOR WATER PICKUP
1
Recovery tank full.
2
Blocked vacuum system (shoes and hoses).
3
Disconnected or damaged vacuum hoses.
4
Recovery tank cover gasket damaged.
NO SOLUTION FLOW
1
No solution in solution tank.
2
Solution Shut-Off Valve
(31)
closed.
3
Solution
Filter
(28)
clogged.
4
Solution pump bad.
5
Spray
Nozzles
(15
and/or
16)
clogged.
SCRUB DECK RAISES WHILE SCRUBBING
1
Debris caught between brushes and brush housing.
2
Bad brush Motor bearing.
NO DETERGENT FLOW
1
Empty detergent cartridge.
2
Plugged or kinked detergent
fl
ow line.
3
Detergent pump wiring disconnected or wired incorrectly.
4
Dry seal cap on detergent cartridge not sealed.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Clean Track L24
Model No.
56317170
Voltage, Batteries
V
24
Battery Capacity
Ah
255
Protection Grade
IPX3
Sound Pressure Level
IEC 60335-2-72: 2002 Amend. 1:2005, ISO 11201
dBA
69.0
Sound Power Level
IEC 60335-2-72: 2002 Amend. 1:2005, ISO 3744
Lwa
86.9
Gross Weight
lbs. /
kg
810 / 367
Vibrations at the Hand Controls (ISO 5349-1)
m/s
2
0.33
Gradeability
Transport
15.4% (8.3°)
Cleaning
12.5% (7.1°)