13
CHECK THE NON RETURN VALVE
If the tank pressure decreases for no apparent reason, it is possible that the
non-return valve is leaking. To check, ensure the tank is under pressure and the
machine switched OFF.
1. Take off the flexible hose and
check if air leaks out from the
valve.
2. If so, unscrew the valve from the
connection and disassemble it as
shown.
3. Clean all the components with a
dry cloth and reassemble the
valve taking care to place the
internal rubber disc(2) as shown.
4. Fasten the valve to the connection and join the flexible hose. If the
leakage persists, the whole valve must be replaced.
REPLACING THE AIR OUTLET FILTER
The compressor must be completely depressurised before carrying out this
procedure.
1. Unscrew the cartridge from the air
filter assembly.
2. Unscrew and replace the small air
filter.
STORAGE
Disconnect the mains plug and ventilate the compressor and any connected
pneumatic tools. Store the compressor in a dry location. Always store upright.
Air Filter
Содержание 2320875
Страница 15: ...15 PARTS DIAGRAM...
Страница 16: ...16 PARTS DIAGRAM...
Страница 18: ...18 WIRING DIAGRAM FLOW CHART...
Страница 19: ...19 DECLARATION OF CONFORMITY...
Страница 20: ......