9
2. Allow the compressor to run for 10
- 15 seconds, with the air outlet
tap, (A) open.
• This will distribute the lubricating
oil.
3. Close the outlet tap and connect
a suitable air hose to the filter/
regulator outlet (B). Connect the
other end to the equipment to be
used.
4. Check the safety valve by pulling
the end cap shown.
•
Pliers will be needed to grip the
end cap and pull against the
spring. Air should hiss out when the
valve is pulled.
5. Adjust the pressure regulator.
• To do this, lift the pressure regulator knob (C), and turn it clockwise to
increase the pressure, anticlockwise to decrease the pressure. The
pressure is shown on the outlet gauge (D).
• To lock the pressure regulator knob, push the pressure regulator knob
down until it clicks into place.
IMPORTANT: Always refer to the accessory manufacturers
recommendations for optimum operating pressures for their equipment.
6. With operating pressure set, open the air outlet tap.
NOTE:
If the machine pumps continuously without cutting out then the
compressor is too small for the application/tool being used, and
damage may result. Consult your Clarke dealer.
NOTE:
DO NOT exceed the duty cycle for the machine (see
Specifications).
SHUTTING DOWN THE COMPRESSOR
1. To shut off the compressor, simply turn the ON/OFF switch to the O (OFF)
position.
2. Close the air outlet tap and trigger the equipment (spray gun, air tool etc.)
to release air from the air hose before disconnecting the hose from the
machine.