8
FITTING THE REGULATOR
1. Fit the regulator into position as
shown.
• Do not overtighten the nut.
SWITCHING THE AIR COMPRESSOR ON
1. To start the compressor, turn the
ON/OFF switch to the ‘I’ (ON)
position - the motor should start
immediately.
NOTE:
If the motor fails to start
immediately, the air receiver
may already be full of air.
Check the tank pressure
gauge (shown on the right).
If you release air, by opening
the air outlet tap, the motor
will start automatically once
the cut-in pressure is
reached.