PROBLEM
PROBABLE CAUSE
REMEDY
The compressor
has stopped
and does not
start.
Bad electrical
connections.
1. Check electrical
connections.
2. Clean and tighten if
necessary.
Overload cutout switch
has tripped.
1. Switch off and wait approx
5 minutes.
2. Press the reset button and
switch on again.
Motor windings burnt out.
1. Contact your Clarke dealer
for a replacement motor.
The compressor
does not reach
the set pressure
and overheats.
Compressor head gasket
blown or valve broken.
1. Return the compressor to
your nearest Clarke service
agent.
Compressor
does not start.
The tank has already fully
pressurised.
1. Open drain valve to expel
air. Compressor should start
again when pressure
reduces.
Air leaking from
the non-return
valve when the
compressor is
not running.
Faulty non-return valve.
1. Drain receiver completely
of air.
2. Remove the valve end
plug,
3. Carefully clean the valve
seat and the gasket
4. Reassemble.
Air pressure
from the
regulator will
not adjust.
The diaphragm within the
regulator body is broken.
1. Replace regulator
The compressor
is noisy & makes
a knocking
sound.
Compressor damaged
and needs overhaul.
1. Return the compressor to
your nearest Clarke service
agent.