BEFORE USE

Before connecting your compressor to the power supply, check the following:-

• Set the ON/OFF switch to the 

OFF position (pushed down).

• Ensure the compressor is 

standing on level ground.

• Make sure that the power 

supply is suitable.

POSITIONING THE COMPRESSOR

This compressor should be positioned 
on a stable, flat surface

.

NOTE: 

Note: the compressor should not be operated on a steep slope or 

floor angle of greater than 15

O

.

If the compressor is placed on a shelf or raised off the ground, it should be 
secured appropriately to prevent it from falling off during use.

Do not cover the compressor. Always position it with good ventilation.

MOVING THE COMPRESSOR

When moving the compressor;

• Always use the handle wherever possible.

• Do not lift by (or place a strain on) the airline fittings or hoses.

• Take care to avoid damaging the valves or fittings.

• Ensure it is switched off and disconnected from the power supply.

Содержание 2242035

Страница 1: ...WARNING Do not use the compressor without reading this manual OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0621 OIL FREE AIR COMPRESSOR MODEL NO RANGER 7 550 PART NO 2242035...

Страница 2: ...t prior notice GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase...

Страница 3: ...front and from the side 3 ALWAYS protect yourself against electric shock NEVER operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to...

Страница 4: ...spect the extension lead regularly and replace if damaged 7 ONLY USE RECOMMENDED PARTS To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to...

Страница 5: ...n position 6 BEFORE EACH USE CHECK THE COMPRESSOR AND HOSE FOR DAMAGED PARTS NEVER use the compressor if it has been damaged in any way Have the compressor repaired by a qualified service engineer DO...

Страница 6: ...s compressor produces a high sound level during operation Ear protection should be worn This compressor contains surfaces which may get hot during operation NEVER operate with the motor housing remove...

Страница 7: ...connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the term...

Страница 8: ...d frame After removing the compressor from its packaging check that it has not been damaged in transit Report any damage immediately to the dealer where the item was purchased ATTACHING THE WHEELS Use...

Страница 9: ...a stable flat surface NOTE Note the compressor should not be operated on a steep slope or floor angle of greater than 15O If the compressor is placed on a shelf or raised off the ground it should be s...

Страница 10: ...hose 3 Turn the outlet valve handle to the on position NOTE The outlet valve is shown without the air hose fitted for clarity TURNING THE COMPRESSOR ON 1 Plug the compressor into the power supply 2 Li...

Страница 11: ...to increase the pressure Turn counterclockwise to decrease the pressure GAUGES 1 The reservoir pressure gauge shows the current pressure in the reservoir 2 The outlet pressure gauge shows the user set...

Страница 12: ...owly open the outlet valve to depressurise the reservoir You will hear a hissing sound as the reservoir depressurises Do not leave the compressor unattended if the reservoir is pressurised DRAINING TH...

Страница 13: ...vice agent MAINTENANCE CAUTION ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CARRYING OUT ANY MANTENANCE DRAINING THE RESERVOIR After use always open the drain valve to make sure that any condensate...

Страница 14: ...nner compatible with the environment By purchasing this product the customer is taking on the obligation to deal with its safe disposal in accordance with the Waste Electrical and Electronic Equipment...

Страница 15: ...compressor does not reach the set pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest CLARKE dealer Compressor does not start The reservoir...

Страница 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Страница 17: ...lat washer 13 Bearing 46 Wheel 14 Rotor 47 Bolt 15 Bearing 48 Drain valve 16 Stator 49 Nut 17 Wave gasket 50 Spring washer 18 Bearing seat 51 Flat washer 19 Overload protector 52 Foot 20 Flat washer 5...

Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UKCA...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY CE...

Страница 20: ......

Отзывы: