Trouble Shooting

Ensure all tests are undertaken by a qualified, trained engineer 
and ensure safe working practices are followed at all times. 

Step 1: Basics
•  Check power connection
•  Ensure power is 12-32V DC 
•  Check the photocell is working - cover photocell, light 

should turn on

•  Ensure power supply is suitable rated to product - check the 

specifications

Step 2: Lamp Test
•  Check current draw of lamp corresponds to specification 
•  Check current of lamp - see instructions for correct current 

settings

To check lamp current ve (red) lead from power 
supply and connect a multimeter (set to 10A) in line with the 
lamp. (One lead of multimeter in common (COM), other lead 
into 10A socket of multimeter; set multimeter to read Amps). 
Refer to PSU Specifications for correct current settings.

Step 3: Set up Camera, Lens and Illumination
•  Check alignment of lamp
•  Check camera lens - fully open at night and set correctly
•  Check model number to performance specification to 

ensure required distance is achievable

Step 4: Call for further assistance
If the lamp is still not delivering the required performance, 
please contact Technical Support for further assistance

Note down: 
•  Model number and serial number of illuminator
•  Camera make and model
•  Lens make and model

Certifications

This product complies with the European Directive 
89/336/EEC Electromagnetic Compatibility and 73/23/
EEC Low Voltage Directive by meeting the following 
standards:

Safety:  

EN60598-1:2008 Electrical Safety

 

 

EN60825-1:2007 LED/Laser Eye Safety

EMC:   

EN61000-6-1:2007

 

 

EN61000-6-3:2007

 

 

EN61000-3-2:2006

 

 

EN61000-3-3:1995 AMD1 & AMD2

FCC:   

FCC CFR Part15. 107 and 15.109

IP: 

 

IP67 in accordance with EN 60529:1992 

 

 

AMD1 7643,1993 AMD2 10931,2000

WEEE:    

Waste Electrical & Electronic Equipment

 

 

European directive 202/96/EC

RoHS:    

Restriction of Hazardous Substances   

 

 

European directive 202/95/EC

This symbol on the product means that the electrical and/or 
electronic equipment to which it relates should be disposed of 
at the end of life separately from domestic household waste.
There are separate collection systems for recycling in the EU. For 
more information please contact the Local Authority or supplier 
of the product.

ACCESSORIES

SMB1

•  ‘L’ Wall mount bracket for single illuminator
•  Compatible with all Clarius infrared & white light 

illuminators

•  Allows up to 180 degrees rotation
•  Fully adjustable (left,right, up & down)

DMB1

•  Dual illuminator mounting bracket compatible with all 

Clarius infrared & white light illuminators

•  Doubles the angle of illumination
•  Increases illumination distance by a factor of 1.4x 

when using two equivalent illuminators

TMB1

•  Triple illuminator mounting bracket compatible with 

all Clarius infrared & white light illuminators

•  Triples the angle of illumination
•  Increases the illumination distance by a factor of 1.7x 

when using three equivalent illuminators

PMB1

•  Pole mounting bracket compatible with all Clarius 

infrared & white light illuminators including SMB1. 
DMB1 and TMB1

•  Supplied with straps to fit 7.5 to 20cm diameter pole

Recommended PSU1

•  Model: ALT-30-24
•  Output: 24V DC / 1.25A Max 
•  Input: 100-250 V AC / 0.45A 50/60Hz
•  Ratings: IP67
•  Dimensions: 200 x 20 x 29mm

Отзывы: